ABB CI506-PNIO PROFINET CANopen Gateway Module
Two serial channels, one CANopen master and local S500 expansion combine multiple field networks behind a PROFINET IO RT device.
Product Overview
ABB CI506-PNIO is an AC500 PROFINET IO RT gateway that combines two configurable serial UART interfaces with one CANopen master interface. The serial ports support RS232, RS422 or RS485 and ASCII communication, while the CANopen master operates at up to 1 Mbit/s and supports the documented network size. A local I/O bus can host up to ten AC500 I/O modules through the TU520-ETH terminal arrangement.
Performance
- Operates as a PROFINET IO RT device for cyclic controller communication.
- Provides two serial UART interfaces for RS232, RS422 or RS485 ASCII devices.
- Includes one CANopen master interface with data rates up to 1 Mbit/s.
- Supports up to 126 CANopen slave nodes under the documented addressing limits.
- Connects as many as ten local AC500 I/O modules through the S500 I/O bus.
- Uses two RJ45 ports integrated in the TU520-ETH terminal unit.
Technical Details
| Manufacturer | ABB |
|---|---|
| Article Number | 1SAP221500R0001 |
| Product Family | AC500 / S500 |
| Network Role | PROFINET IO RT gateway |
| Serial Interfaces | 2 UART interfaces |
| Serial Physical Layers | RS232, RS422 or RS485 |
| Serial Protocol | ASCII |
| CAN Interface | 1 CANopen master |
| CANopen Data Rate | Up to 1 Mbit/s |
| CANopen Nodes | Up to 126 slaves |
| Local I/O Expansion | Up to 10 AC500 I/O modules |
| Terminal Unit | TU520-ETH |
| Lifecycle | Active |
System Integration
- Use the TU520-ETH terminal unit and verify the 24 V UP/ZP supply before commissioning.
- Map the gateway as a PROFINET IO RT device in the controller project.
- Set serial physical layer, baud rate and ASCII framing separately for both UART channels.
- Engineer CANopen bit rate, node IDs and termination for the complete bus.
- Archive the PROFINET device name, CANopen configuration and local I/O map before maintenance.
Applications
- Connecting CANopen field devices to a PROFINET-controlled machine.
- Integrating two legacy serial devices together with CANopen equipment.
- Remote I/O stations that require up to ten local S500 modules.
- Protocol migration projects retaining existing ASCII or CANopen assets.
- Replacement of an installed CI506-PNIO with the same terminal and network configuration.
FAQ
Which field networks are combined by CI506-PNIO?
It combines PROFINET IO RT with two serial interfaces and one CANopen master interface.
How does CI506-PNIO differ from CI504-PNIO?
CI506-PNIO has two serial interfaces plus CANopen master; CI504-PNIO has three serial interfaces and no documented CANopen master.
What is the maximum documented CANopen data rate?
ABB documents CANopen operation up to 1 Mbit/s.
How many local S500 I/O modules can the gateway support?
The local I/O bus supports up to ten AC500 I/O modules.
Which terminal unit is required?
CI506-PNIO uses the TU520-ETH terminal unit with two RJ45 connections.
What configuration should be preserved before replacement?
Save the PROFINET device identity, both serial-port settings, CANopen node plan and local I/O mapping.
Recommended Models
| PXA30-RS | ALM-1 | V-U0047 839-000540 |
| EB401-10 | PSR-SCP-230UC/ESAM4/3X1/1X2/B | AM-200 |
| PC-E984-265 | 20-0635-30 | CP-8800-A-KEM |
| Ex09115666 | MP-6000 | A13HD |
| QUINT-UPS | 7940016563 | MI-MCP-FLEX |
| SNZ4052K | EKA163B 084B8574 | SCREENX-CT2 |
| DIN-2MC2 6501745 | CL06A300M1 | 6197-102-500 |
| MCP250M | RHT-WM-485-LCD | ITEM3-2000U8000 |
| KNX /644692 | L24734-F655-A5 | 70-315-11 |
| 3912-20 | 6ES7331-7NF00-0AB0 | 6ES7307-1EA01-0AA0 |