An eight-channel normally-open relay output module with two isolated groups and switching support for 24 V DC, 24 V AC and 120/240 V AC loads.
Product Overview
ABB DO571, article 1TNE968902R2202, provides eight normally-open relay outputs divided into two isolated groups of four. The relay contacts accommodate low-voltage DC or AC signals as well as 120/240 V AC loads within the documented current and switching limits.
Performance
- Eight normally-open relay outputs are arranged as two groups of four.
- Each channel supports up to 2 A for the documented resistive voltage classes.
- Typical relay switching delay is 10 ms in both directions.
- Maximum group current is 8 A.
- ABB specifies 100,000 relay-contact cycles at rated load.
Technical Details
| Manufacturer | ABB |
|---|---|
| Article Number | 1TNE968902R2202 |
| Product Family | AC500 S500-eCo |
| Output Count | 8 normally-open relay outputs |
| Output Grouping | 2 isolated groups of 4 channels |
| Rated Voltage Classes | 24 V DC, 24 V AC, 120 V AC or 240 V AC |
| Maximum Resistive Current per Channel | 2 A |
| Maximum Pilot-Duty Current at 240 V AC | 1.5 A |
| Maximum Current per Group | 8 A |
| Typical Switching Delay | 10 ms |
| Output Data Length | 1 byte |
| Maximum Lamp Load | 200 W at 230 V AC; 30 W at 24 V DC |
| Protection | External fusing required |
| Terminal Block | One 11-pin block, ordered separately |
| Maximum Module Dissipation | 2 W |
| Lifecycle | Active |
System Integration
- Fit one compatible 11-pin S500-eCo terminal block selected for screw or spring connection.
- Supply the relay coils from 24 V DC at terminal 20 as described by ABB.
- Provide external contact protection and load suppression; relay outputs are not internally short-circuit protected.
- Separate low-voltage and mains-voltage wiring according to the applicable installation requirements.
- Hot swap is not supported for DO571; remove all hazardous voltage before service.
Applications
- Relay isolation for mixed low-voltage and mains-voltage control circuits.
- Contactor, pilot and signaling loads within the documented contact ratings.
- Compact S500-eCo stations requiring two isolated groups of four outputs.
- Maintenance replacement where normally-open relay behavior must be retained.
- Active spare planning for ABB article 1TNE968902R2202.
FAQ
What contact type does DO571 provide?
The module provides eight non-latching normally-open relay outputs.
How are the relay outputs grouped?
They are divided into two galvanically isolated groups of four channels.
What is the maximum channel current?
The resistive-load rating is up to 2 A, with a lower 1.5 A limit for 240 V AC pilot duty.
How fast do the relays switch?
Typical delay is 10 ms for both opening and closing transitions.
Does DO571 need external fuses?
Yes. The contacts are not short-circuit or overload protected, so external protection is required.
Which terminal block is used?
DO571 uses one 11-pin S500-eCo terminal block, ordered separately.
Recommended Models
| CONV0/10A0 | QSE-CI-DMX | PCX3733 CH-PCX3733-0 |
| K910B | 6ES7323-1BL00-0AA0 | SO816N.A001 |
| GW-CRPS550 | DE1-122D3FN-N20N | CV-S101 |
| WLP450C | OT80F8 | 346050 |
| 1860114A | 616102R5Z31002M | LM631 |
| MTL4504 | EX-9520 | IP20 |
| NCGCM | XFL823A , XS823 | Jan-26 |
| ABB 2CDG 110 044 R0011 | SC8551A005MS.24/DC | PTL-12-109 TLS-2200 |
| SMC-50-LCLC | CR104PLG22W | SAVS48EU3 |
| ABB CP-E24/5.0 1SVR427034R0000 | 203LS-D | E244-16C-G-LS-SN-CR-SQ-BR |