ABB DSQC1030 Scalable I/O Digital Base
An EtherNet/IP-connected ABB robotics base device with 16 digital inputs, 16 digital outputs and expansion for four add-on devices.
Product Overview
DSQC1030 is the digital base device in ABB Robotics Scalable I/O. It provides 16 digital inputs and 16 digital outputs and can be combined with up to four compatible add-on devices.
Two Ethernet connectors support network integration, while separate terminals handle logic power, process power, digital inputs and digital outputs. Status LEDs report each channel and the power, network and module states.
Performance
- Exchanges digital robot-cell signals over EtherNet/IP.
- Provides 16 local digital inputs and 16 local digital outputs in the base assembly.
- Extends the station with up to four supported Scalable I/O add-on devices.
- Reports I/O, network, module and power condition through dedicated status LEDs.
Technical Details
| Manufacturer | ABB Robotics |
|---|---|
| Model | DSQC1030 |
| Product Role | Scalable I/O digital base |
| Digital Inputs | 16 |
| Digital Outputs | 16 |
| Add-On Capacity | Up to four compatible devices |
| Network | EtherNet/IP |
| Ethernet Connectors | Two |
| X1 | Digital outputs and process power |
| X2 | Digital inputs |
| X4 | Logic power |
| Status LEDs | DI 1–16, DO 1–16, PWR, NS, MS and Ethernet |
System Integration
- Record the DSQC1030 IP address, EtherNet/IP assemblies, RobotWare configuration and add-on order before replacement.
- Separate logic and process power correctly and verify common reference and load protection at X1, X2 and X4.
- Restore the ABB I/O device configuration and confirm that every add-on module is discovered in the intended order.
- Test each input, output, network status and robot safety interlock under controlled conditions.
Applications
- Robot grippers and tooling
- Conveyor and fixture handshakes
- ABB robot-cell digital I/O expansion
FAQ
How many channels are built into DSQC1030?
DSQC1030 provides 16 digital inputs and 16 digital outputs in the base device.
How many add-on devices can DSQC1030 support?
ABB documents support for up to four compatible Scalable I/O add-on devices.
What data should be backed up before replacing DSQC1030?
Save the RobotWare system, I/O configuration, IP address, EtherNet/IP assembly setup, signal mapping and add-on sequence.
Can DSQC1030 be used without checking process power?
No. Logic power and output process power have distinct connections, and the load supply and protection must be verified.
What should be tested after DSQC1030 replacement?
Check network and module status, all 32 base channels, add-on discovery, robot program handshakes and safety-related interfaces.
Recommended Models
| SPV 110.240.9450b | ASLS2000 2120 | WE 25-343 |
| Siemens 6RA2228-6GS22-0 | X20BM15 | C200H-0C225 |
| X67AI1223 | SEW SA67 DRN90L4/BE2/C | 8BVI0014HWDS.000-1 |
| OKAN 2.7802.2.31-51.-00.00 | 0820525720 | C054045C001B |
| X20SC0806 | SEW R17 DRS71M4/MM07/MO | HDP5000 |
| 330130-045-00-05 | DE1-122D3FN-N20N | Phoenix Contact 2727349 |
| EDS-305 | 8LSA44.EB022D000-3 | NRT405F902 |
| 6NH9821-0BC12 | E-E720MBA | MI 40FP N12 i=10 |
| 1H11G-301 | MTN6725-0003 | SL10.305 |
| SH070/60030/0/0/00/00/00/11/00 SH30703P02F2000 | RF37 DRN80M4/BE05 | FIS-0710-0164 |