Home>DCS>ABB GSH204 AC-C63/0.03 Four-Pole RCBO

Hot Categories

ABB GSH204 AC-C63/0.03 Four-Pole RCBO

ABB GSH204 AC-C63/0.03 Four-Pole RCBO

Item NO.: 3742393

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameABB GSH204 AC-C63/0.03 Four-Pole RCBO
  • Item NO.3742393
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandABB
  • Creation Time2026-08-20
ABB GSH204 AC-C63/0.03 Four-Pole RCBO | HTML Preview

ABB GSH204 AC-C63/0.03 Four-Pole RCBO

ManufacturerABBModelGSH204 AC-C63/0.03Product TypeFour-Pole Type AC RCBO

01Product Identification

ABB GSH204 AC-C63/0.03 is a four-pole residual-current operated circuit breaker with integral overcurrent protection from the GSH200 family. Its exact designation identifies Type AC residual-current detection, a C tripping characteristic, 63 A rated current, and 0.03 A residual operating current.

Configuration Control

Match the complete model, ratings, ordered variant, installed system, connections, and protection requirements before ordering.

02Key Features

  • Combines residual-current protection and overcurrent protection in one modular device.
  • Four-pole switching and protection format for the documented GSH204 version.
  • Type AC detection for sinusoidal alternating residual currents.
  • C-curve overcurrent characteristic identified directly by the model code.
  • Thirty-milliampere residual operating-current sensitivity.
  • Exact 63 A current variant documented in the ABB GSH200 product range.

03Engineering Data

Manufacturer ABB
Exact Model GSH204 AC-C63/0.03
Product Family GSH200
Product Category RCBO - residual-current circuit breaker with overcurrent protection
Number of Poles 4
Residual-Current Type Type AC
Tripping Characteristic C curve
Rated Current 63 A
Rated Residual Operating Current 0.03 A (30 mA)
Operating Characteristic Instantaneous residual-current version

04System Integration

Integration Checklist

  • Match all four conductors and the original terminal arrangement when replacing an installed unit.
  • Confirm the distribution-system voltage, earthing arrangement, conductor sizing, and protective-device coordination before installation.
  • The exact Type AC, C-curve, 63 A, and 30 mA characteristics must be retained unless an electrical design review specifies otherwise.
  • Use the applicable ABB installation documentation and local electrical regulations for testing and commissioning.

Verified Identity

Model: GSH204 AC-C63/0.03

Type: Four-Pole Type AC RCBO

Manufacturer: ABB

05Applications

  • Four-pole final or distribution circuits requiring combined residual-current and overcurrent protection.
  • Circuits specified for Type AC residual-current detection and a 30 mA operating threshold.
  • Installations requiring a C-curve 63 A RCBO within the documented GSH200 range.

06Lifecycle

  • Preserve the complete designation GSH204 AC-C63/0.03 when sourcing a like-for-like replacement.
  • Do not substitute a GSH201, GSH202, or GSH203 device because the pole configuration is different.
  • Do not substitute Type A, another trip curve, another current rating, or another residual-current threshold without an engineering review.
  • Installation, isolation, insulation testing, and residual-current testing must be performed by qualified personnel.
  • No verified exact net weight was available, so no product-weight value is presented.

FAQFrequently Asked Questions

What type of protective device is GSH204 AC-C63/0.03?

It is a four-pole RCBO combining residual-current and overcurrent protection.

What is its rated current?

The exact model designation identifies a 63 A rated current.

What is the residual operating current?

The /0.03 designation corresponds to 0.03 A, or 30 mA.

What does AC indicate?

It identifies Type AC residual-current detection for sinusoidal alternating residual currents.

What does C63 indicate?

It identifies a C tripping characteristic and a 63 A rated current.

Can a device with a different number of poles be substituted?

Not as a direct replacement. The four-pole circuit arrangement and all protection characteristics must be matched.

You May Also Like