Home>DCS>ABB PM5630-2ETH AC500 V3 Processor Module

Hot Categories

ABB PM5630-2ETH AC500 V3 Processor Module

ABB PM5630-2ETH AC500 V3 Processor Module

Item NO.: 3758035

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameABB PM5630-2ETH AC500 V3 Processor Module
  • Item NO.3758035
  • Weight0.1350 kg = 0.2976 lb = 4.7620 oz
  • CategoryDCS
  • BrandABB
  • Creation Time2026-09-03
AC500 V3 | Active processor revision

ABB PM5630-2ETH AC500 V3 Processor Module

An 8 MB standard controller with two independent Ethernet interfaces, RS-232/485, CAN, display, memory-card support and a 24 V DC supply.

BrandABB
ModelPM5630-2ETH
Identification1SAP131000R0378
01 

Product Overview

PM5630-2ETH is an AC500 V3 standard processor module designed for the TB56xx-2ETH terminal-base platform. Active revision 3 article 1SAP131000R0378 provides 8 MB memory, two independent onboard Ethernet interfaces and integrated serial and CAN connectivity.

The processor module includes a display and memory-card slot but requires a compatible terminal base to form a complete controller. Revision 3 retains the function of revision 2 while introducing specific firmware and Automation Builder requirements.

02 

Performance

  • Runs AC500 control applications with 8 MB memory.
  • Provides two independent RJ45 Ethernet TCP/IP interfaces for separate network assignments.
  • Supports Modbus TCP, web-server functions, IEC 60870-5-104 or selectable Ethernet-based protocols in the documented configuration.
  • Adds one RS-232/485 interface and one CAN interface through the matching terminal-base system.
  • Uses the integrated display for controller status and service interaction.
  • Operates on 24 V DC with a typical module-only current of 110 mA.
03 

Technical Details

Manufacturer ABB
Product Family AC500 V3
Model PM5630-2ETH
Active Article Number 1SAP131000R0378
Hardware Revision Revision 3
Memory 8 MB
Supply Voltage 24 V DC
Typical Module Current 110 mA
Ethernet Interfaces 2 independent RJ45 TCP/IP interfaces
Serial Interface 1 RS-232/485
CAN Interface 1
Display Integrated
Memory Card Supported
Required Terminal Base TB56xx-2ETH family
Lifecycle Revision 3 active; revision 2 R0278 Classic
04 

System Integration

  • Mounts on the specified TB56xx-2ETH terminal base, which provides the controller connection environment.
  • Supports architectures that keep two Ethernet networks logically separated or use the interfaces for different protocols.
  • Can connect serial and CAN communication through the installed controller hardware configuration.
  • Requires consistent firmware across revision 2 and revision 3 processors used in the same upgraded application.
  • Must be engineered with Automation Builder 2.6.0 or later when revision 3 hardware is introduced.
05 

Applications

  • AC500 control stations that require two independently configured Ethernet networks.
  • Process or infrastructure controllers using Modbus TCP or IEC 60870-5-104.
  • Machines that combine Ethernet, serial and CAN communication in one CPU assembly.
  • Revision 2 controller replacement after the application and firmware are upgraded for revision 3.
  • Standard AC500 V3 systems built on a compatible TB56xx-2ETH terminal base.
06 

FAQ

Which article identifies the active PM5630-2ETH revision?

Active revision 3 is article 1SAP131000R0378; revision 2 R0278 is in the Classic phase.

Can the processor operate without a terminal base?

No. PM5630-2ETH requires a compatible TB56xx-2ETH terminal base to form the controller assembly.

What software baseline applies to revision 3?

ABB requires Automation Builder 2.6.0 or later and boot/CPU firmware V3.6.x or later.

Can revision 3 be downgraded below firmware V3.6.0?

No. The revision 3 hardware cannot be used with an earlier firmware level.

Are the two Ethernet ports only an unmanaged switch?

They are documented as two independent onboard Ethernet TCP/IP interfaces, allowing separate interface assignments.

What should be retained before an R0278-to-R0378 exchange?

Retain the project, firmware, terminal-base model, both Ethernet configurations, serial/CAN settings and application backup.