ABB TB521-ETH 1SAP112100R0270 Terminal Base
An Ethernet terminal base that carries one AC500 V2 processor, two communication modules, two serial interfaces and the local S500 I/O-bus connection.
Product Profile
TB521-ETH expands the AC500 V2 terminal-base arrangement to two communication-module positions beside one processor position. The Ethernet version provides the RJ45 network connection required by the matching Ethernet processor family.
Controller supply, serial interfaces, FieldBusPlug access and the local I/O bus are presented at the base so the installed CPU and communication modules can form one mechanically integrated station.
Technical Data
| Manufacturer | ABB |
|---|---|
| Model | TB521-ETH |
| Order Code | 1SAP112100R0270 |
| System Family | AC500 V2 |
| Processor Positions | 1 |
| Communication-Module Positions | 2 |
| Network Connection | Ethernet RJ45 |
| Serial Connectivity | Two RS-232 / RS-485-capable interfaces |
| COM1 Hardware | 9-pole removable terminal block |
| COM2 Hardware | 9-pole female D-sub connector |
| FieldBusPlug Connection | 5-pole male M12 interface |
| Expansion Bus | S500 I/O bus |
| Supply Terminal | Removable 5-pole connection for 24 V DC |
| Base Length | 123.5 mm |
| Assembly Height | 135 mm |
| Lifecycle Phase | Active |
System Role
The terminal base is the physical carrier and interface breakout for the AC500 processor station. Its second communication-module position distinguishes it from TB511-ETH and supports controller arrangements needing two base-mounted communication modules.
The right-side I/O-bus connection extends the local station to S500 terminal units. The actual network and protocol behavior depends on the processor and communication modules installed on the base.
Compatibility
- Use an Ethernet AC500 processor whose order-code revision is approved for the R0270 terminal-base generation.
- PM57x-ETH, PM58x-ETH and PM59x-ETH processors with R0271 endings are paired with TB5x1-ETH bases using R0270 endings.
- TB521-ETH-XC is a separate extended-condition version and must be selected together with compatible XC system components.
- PM591-2ETH is assigned to TB523-2ETH rather than TB521-ETH.
- The number and type of communication modules must remain within the two available communication positions.
Applications
- AC500 V2 controller stations that need two communication modules beside the CPU.
- Ethernet-connected control panels using an RJ45 processor-network interface.
- Local S500 I/O expansion from the processor terminal base.
- Stations combining serial or FieldBusPlug functions with two communication-module slots.
- Maintenance replacement after the installed processor, modules and base revision are verified.
FAQ
What is the principal difference between TB521-ETH and TB511-ETH?
TB521-ETH provides two communication-module positions, while TB511-ETH provides one.
Can PM591-2ETH be mounted on TB521-ETH?
No. ABB assigns PM591-2ETH to the TB523-2ETH terminal base.
Which network connector is provided?
The Ethernet version includes one RJ45 network connector.
How many processor modules does the base accept?
It has one processor-module position.
Can the base extend a local S500 station?
Yes. The side I/O bus connects compatible S500 I/O terminal units.
What must be recorded before replacement?
Record the processor order code, both communication modules, network and serial wiring, FieldBusPlug connection, I/O chain and supply terminals.
Recommended Models
| CONTREXGRP/1/PV2122-01077-1 | Adam-5000/TCP | EV669 |
| DM4T 4940275 | 216690 HIC2822 | ABB 520AOD01 1KGT024500R0001 |
| LNL-1003MK | T8123 PoE-30W 5014-201-01 | NS-SDW-210 |
| 28120D-CS | LTMR08MFM | 6197-102-500 |
| 751107 | XD50-PC | ABB 1KGT033100R0001 520AID01 |
| PN 301508 | DPM-PGD3V 744745-003 | 2CDG 110 153 R0011 |
| IE-SW-BL05-5TX | 10937963 | 3HE15377AARA01 SFP28 |
| Daliknx2Ch | XU1-DC-2 | IM5019 IME3020-FPKG |
| RTX40 | 719-DC-RC | 772476 |
| KFD2-STC4-120 | 48502100 | ADC827F |