ABB TB5640-2ETH AC500 V3 Terminal Base
A four-slot communication terminal base for selected PM56xx-2ETH processors, with dual Ethernet, CAN, serial and S500 local I/O-bus connections.
Product Overview
TB5640-2ETH expands an AC500 V3 controller station with four communication-module positions. Its wider base is intended for systems that need several network interfaces alongside the processor-integrated Ethernet, CAN and serial ports.
Processor compatibility narrows at this expansion level: the four-slot base supports PM5650-2ETH, PM5670-2ETH and PM5675-2ETH rather than every PM56xx processor.
Performance
- Hosts up to four compatible communication modules next to one processor module.
- Keeps processor networking and added communication hardware on a single coordinated terminal-base assembly.
- Provides two Ethernet RJ45 ports plus CAN and COM1 access from the processor side.
- Connects the controller to a local S500 I/O chain through the AC500 I/O bus.
- Supports either horizontal or vertical cabinet mounting when the complete station installation limits are observed.
Technical Details
| Manufacturer | ABB |
|---|---|
| Model | TB5640-2ETH |
| Order Code | 1SAP114300R0278 |
| Product Family | AC500 V3 |
| Processor Positions | 1 |
| Communication-Module Positions | 4 |
| Compatible Processors | PM5650-2ETH, PM5670-2ETH and PM5675-2ETH |
| Ethernet Interfaces | 2 x RJ45 |
| Additional Interfaces | 1 x CAN and 1 x COM1 serial |
| Supply | 24 V DC through removable 5-pole spring terminal |
| Maximum Current Consumption | 0.6 A including installed system components |
| Protection | IP20 |
| Mounting | 35 mm DIN rail or screw mounting |
| Lifecycle Phase | Active |
System Integration
- Do not pair TB5640-2ETH with PM5630-2ETH; select one of the documented PM5650, PM5670 or PM5675 processor types.
- Communication slots can receive compatible communication modules or an AC500-S module, with no more than one AC500-S module on a terminal base.
- Plan network addressing, connector access and cable routing separately for all four option positions.
- Document the left-to-right slot population and project configuration before replacing the base.
Applications
- AC500 V3 control stations that coordinate several industrial networks from one processor assembly.
- Machines combining processor Ethernet with fieldbus or serial communication modules.
- Controller retrofits requiring four communication-module positions and local S500 I/O expansion.
- Cabinet standardization around PM5650, PM5670 or PM5675 processor platforms.
- Maintenance projects where the terminal-base wiring is retained while plug-in modules are exchanged.
FAQ
Can PM5630-2ETH be installed on TB5640-2ETH?
No. ABB lists the four-slot base for PM5650-2ETH, PM5670-2ETH and PM5675-2ETH processors.
How many communication-module positions are available?
The base provides four positions in addition to the processor position.
Can safety and communication modules share the base?
Compatible communication modules or an AC500-S module can be used, but only one AC500-S module is allowed on a terminal base.
Which processor interfaces remain available?
The assembly provides access to two Ethernet ports, one CAN interface and one COM1 serial interface.
What should be recorded before replacing the terminal base?
Record the processor order code, the left-to-right slot population, network settings and field-connection labels.
Is TB5640-2ETH the same as the XC version?
No. The standard and wide-temperature XC versions are separate orderable products.
Recommended Models
| 5502DAL | 211052-ad | DMC-4K-C-HDCP2 6507321 |
| DDNI485 | DCB-0001 | SBD2D-06 |
| 2002-70V | 3EM17860BTBV | SCB-5003P 1280H |
| GE NMTCV2 REF. 124901 | DM-RMC-100-C | QBE2003-P16 |
| 21029771 | VS-ZP3102 | MX153 |
| 4UI/4AO ITEM3-2000U040400 | HJK7000 | ABB 3BSE008510R1 DO810 |
| 1768-ENBT/A | E1ZM10 | ABB MT701.2 |
| OT30HONA | RPM10-NIST | QUINT4-DIODE |
| RB2 BA4 | T2500 | EWPC974 T1L2CWC312 |
| BZMD1-A125 | LUCA1XFU | GLB161.1E |