Allen-Bradley 20F11RC015JA0NNNNN PowerFlex 753 AC Drive
An active 15.4 A PowerFlex 753 drive rated at 7.5 kW normal duty and 5.5 kW heavy duty, with embedded I/O and filtered input.
Technical Summary
20F11RC015JA0NNNNN is a Frame 1 PowerFlex 753 drive for 400 V AC three-phase motor applications. It combines embedded I/O with forced-air cooling and an open-type panel construction.
The catalog configuration includes AC input with DC terminals, an input filter with the preferred common-mode jumper position, a dynamic-braking transistor and a blank HIM location.
Specifications
| Manufacturer | Rockwell Automation |
|---|---|
| Brand | Allen-Bradley |
| Catalog Number | 20F11RC015JA0NNNNN |
| Product Family | PowerFlex 753 |
| Input Supply | 400 V AC, 3 phase |
| Output Current | 15.4 A |
| Power Rating | 7.5 kW normal duty; 5.5 kW heavy duty |
| Frame | 1 |
| I/O Configuration | Embedded I/O |
| Protection | Standard protection |
| Cooling | Forced air |
| Input Arrangement | AC input with DC terminals and precharge |
| Enclosure | IP20, NEMA / UL open type |
| Filtering | Filtered with common-mode jumper installed |
| Dynamic Braking | DB transistor included |
| Human Interface | Blank; no HIM |
| Lifecycle Status | Active |
Features
- Embedded I/O supports local machine-control signals without requiring an I/O option for basic integration.
- The Frame 1 power structure provides the documented 15.4 A rating in a compact open-type assembly.
- PowerFlex 750-Series option architecture allows additional functions to be selected after compatibility review.
- The DB transistor provides the switching element for an externally designed dynamic-braking circuit.
- Filtered input construction and the installed common-mode jumper define the electrical configuration of this suffix.
Compatibility
- Use with a 400 V three-phase motor whose current and duty profile fit the published normal- or heavy-duty rating.
- Provide a control enclosure and cooling arrangement suitable for the IP20 open-type drive.
- Select any option cards and operator interface by verified PowerFlex 753 slot, voltage and firmware compatibility.
- Review braking duty before choosing an external resistor; the transistor alone does not define the complete braking circuit.
- Do not substitute another 20F suffix without comparing frame, input arrangement, filtering, I/O and HIM selections.
Replacement
- The exact JA0 catalog configuration is listed by Rockwell Automation as Active.
- The earlier AA0 variant was assigned a direct replacement to this JA0 form, but installed-system details still require verification.
- Back up parameters and document the motor, I/O, braking circuit and option modules before a planned exchange.
- After installation, validate protective settings, motor direction and command sources before production operation.
FAQ
What duty ratings apply to this drive?
The exact catalog number is rated 7.5 kW normal duty and 5.5 kW heavy duty.
Which physical frame is specified?
Rockwell Automation identifies it as Frame 1.
Is an operator keypad included?
No. The catalog configuration has a blank HIM position.
What does the filtered suffix indicate?
It identifies an input filter with the preferred common-mode jumper arrangement.
Can the included DB transistor operate without further selection?
A suitable external resistor, protection and braking-duty design must still be engineered.
Which information should accompany a replacement enquiry?
Include the full suffix, motor duty, parameter backup, I/O map, braking arrangement and installed options.
Recommended Models
| ARK 3382 | RF432 | CS-AMS8 RS485 |
| AUTA 715403 | XFL 523 | XFC3D06001 |
| AT-CV41R | QAM2171.040 | TB-C |
| LA9D50978 | KE 1051 A004-9 | Trio-PS-2G/1Ac/24DC/10 |
| VF20T | ABB STD-420 | 97038401 1771-P4R |
| SC8551A005MS.24/DC | SB-4BS-EU/BG | LC35494 HT28 |
| 751322 220-000437-403 | DSP-2 v2 ,EN54-16 ,F01U101303 | TN2200 |
| 189784 KFD2-EB2.R4A.B | PH-3A-HG | Luna-TFT43 |
| 120BA011/120B1011 | AX82 | 88974031 CB20 |
| 1PH UNO-PS/1AC/12DC/30W | 1466.1 | ABB 6126/01-866-500 / 2CDG006116R0201 |