Home>PLC>Allen-Bradley 2711P-T10C4D1 PanelView Plus 1000 Color Touch Terminal

Hot Categories

Allen-Bradley 2711P-T10C4D1 PanelView Plus 1000 Color Touch Terminal

Allen-Bradley 2711P-T10C4D1 PanelView Plus 1000 Color Touch Terminal

Item NO.: 2711P-T10C4D1

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameAllen-Bradley 2711P-T10C4D1 PanelView Plus 1000 Color Touch Terminal
  • Item NO.2711P-T10C4D1
  • Weight2.6000 kg = 5.7320 lb = 91.7123 oz
  • CategoryPLC
  • BrandAllen-Bradley
  • Creation Time2026-08-09
  • Allen-Bradley 2711P-T10C4D1 PanelView Plus 1000 color touch HMI, discontinued by Rockwell Automation on December 31, 2012. Official migration path: 2711P-T10C4D8 (also discontinued) to active 2711P-T10C22D9P. The current replacement requires Ethernet communication, an application-resolution review, and adapter plate 2711P-RAAT10 for drop-in installation.
Allen-Bradley · PanelView Plus 1000

2711P-T10C4D1 Color Touch Terminal

10.4-inch color HMI with analog resistive touch input, EtherNet/IP and RS-232 communications, and 24V DC power.

Catalog Number2711P-T10C4D1
LifecycleDiscontinued
Discontinued DateDecember 31, 2012

Product Information

The Allen-Bradley 2711P-T10C4D1 is a PanelView Plus 1000 operator terminal. It combines a 10.4-inch color active-matrix TFT display with analog resistive touch input, EtherNet/IP and RS-232 communication interfaces, and 24V DC input power. Rockwell Automation identifies this catalog number as discontinued.

  • 10.4-inch color active-matrix TFT LCD
  • 640 × 480 pixel resolution with 18-bit color
  • Analog resistive touch screen
  • EtherNet/IP and RS-232 communications
  • USB peripheral and printing support
  • 24V DC input power

Technical Data

Catalog Number 2711P-T10C4D1
Product Family PanelView Plus 1000
Display 10.4 in color active-matrix TFT LCD
Display Area 211 × 158 mm
Resolution / Color 640 × 480; 18-bit color
Operator Input Analog resistive touch; 1 million presses; 10...110 g operating force
Backlight CCFL; 50,000 h minimum at 25 °C
Communications EtherNet/IP and RS-232
Internal Flash 64 MB; 20 MB application flash for Series A–D logic modules
Expansion Type I CompactFlash, up to 512 MB
Input Power 24V DC nominal; 18...32V DC
Power Consumption 70 W maximum; 39 W typical at 24V DC
Dimensions (H × W × D) 248 × 329 × 55 mm
Panel Cutout (H × W) 224 × 305 mm
Approximate Weight 2.6 kg
Operating Temperature 0...55 °C
Storage Temperature −25...70 °C
Relative Humidity 5...95%, noncondensing
Maximum Altitude 2000 m
Enclosure Ratings NEMA 12, 13, 4X indoor; IP54; IP65
Shock 15 g operating; 30 g nonoperating at 11 ms

Software and Applications

PanelView Plus terminals are configured with FactoryTalk View Machine Edition Station applications. Rockwell Automation's migration guidance states that PanelView Plus applications at version 3.2 or later can be migrated to PanelView Plus 7 terminals. The application should be backed up, converted in a supported FactoryTalk View Studio environment, validated for the destination firmware, and functionally tested before production use.

Typical uses include operator control and monitoring, machine status and diagnostics, alarm and event display, production data entry, and visualization for EtherNet/IP-connected automation systems.

Lifecycle and Discontinuation

2711P-T10C4D1 lifecycle status: Discontinued.

Manufacturer discontinuation date: December 31, 2012.

The catalog number is no longer part of Rockwell Automation's active product offering. Availability shown on this site relates to existing inventory and does not change the manufacturer's lifecycle status.

Manufacturer Migration Path

Original Terminal
2711P-T10C4D1
Discontinued December 31, 2012
→
Direct Catalog Conversion
2711P-T10C4D8
Discontinued December 30, 2021
→
Current Engineering Replacement
2711P-T10C22D9P
Active / Preferred

Rockwell Automation's product lifecycle information identifies 2711P-T10C4D8 as the direct catalog conversion for 2711P-T10C4D1. Because 2711P-T10C4D8 is also discontinued, its engineering replacement is 2711P-T10C22D9P.

Replacement Assessment

Catalog Number Manufacturer Position Replacement Level Key Considerations
2711P-T10C4D8 Direct catalog conversion; discontinued December 30, 2021 Historical direct conversion Not the current active choice.
2711P-T10C22D9P Engineering replacement; Active / Preferred Current recommended migration path Not a completely identical, no-change replacement. Mechanical, communications, display, firmware, and application review are required.
2711P-T10C21D8S PanelView Plus 7 Standard option Alternative only where Standard limits are acceptable Maximum 100 screens, 500 alarms and one controller; Ethernet, touch and DC configuration. The Performance adapter plate is not specified for this Standard terminal.

Migration Requirements for the Current Replacement

Mechanical installation
Use Rockwell Automation adapter plate 2711P-RAAT10 when a drop-in installation of the PanelView Plus 7 Performance terminal is required. Confirm enclosure depth, mounting clearance and environmental requirements.
Communications
PanelView Plus 7 terminals use Ethernet communication. Applications that currently depend on the 2711P-T10C4D1 RS-232 port must be redesigned for Ethernet communication or provided with an engineered external conversion solution.
Display and graphics
The display resolution changes from 640 × 480 to 800 × 600. Review every display, popup, object position, font, bitmap and navigation element; resize or reposition items as needed.
Application conversion
PanelView Plus applications version 3.2 and later are supported by the migration path. Back up the source project, convert it with a supported FactoryTalk View Studio version, select compatible destination firmware, and validate communications, alarms, recipes, trends, security and macros.
Commissioning
This is not a guaranteed plug-and-play replacement. Confirm power, wiring, network architecture, controller shortcuts, peripherals and regulatory requirements, then perform offline testing and controlled on-machine commissioning.
Selection note: Final replacement selection must be based on the installed terminal's complete catalog configuration, application, communications, firmware, mounting and regulatory requirements.