Bently Nevada 129525-0050-02 50 ft External Termination Block Cable
A 50 ft assembled interconnect for compatible rack I/O and separately mounted termination hardware.
Technical Summary
129525-0050-02 is a Bently Nevada external termination block cable identified for a 50 ft (15 m) configured length. It connects compatible rack I/O hardware to its separately mounted external termination assembly.
The cable is an installation accessory rather than a measuring module. Selection therefore depends on the associated I/O module, external terminal block, connector arrangement and required routing length.
Specifications
| Manufacturer | Baker Hughes Bently Nevada |
|---|---|
| Complete Model | 129525-0050-02 |
| Product Type | External termination block cable |
| Configured Length | 50 ft / 15 m |
| Assembly Form | Assembled cable |
| System Function | Rack I/O to external termination block interconnect |
| Installation Context | Panel or rack external-termination architecture |
Features
- Provides a 50 ft (15 m) interconnect path between rack I/O and external termination hardware.
- Arrives as an assembled cable configuration.
- Supports separation of field terminal blocks from the rack location.
- Keeps the length code and assembly suffix together in one complete ordering reference.
- Allows panel wiring to remain at the external termination block during rack-side service.
Compatibility
- Match 129525-0050-02 to the documented external termination block and rack I/O module.
- Confirm connector gender, keying and pin assignment at both ends.
- Verify that the 50 ft route fits the enclosure and tray path without exceeding bend limits.
- Do not use an external-termination cable with an internal-termination I/O module.
- Review the complete monitoring or temperature-module assembly before ordering.
Replacement
- Preserve the full 129525-0050-02 configured cable designation.
- Label both ends and photograph connector orientation before disconnecting the existing cable.
- Inspect connectors, backshells, shielding and the complete cable route.
- Avoid sharp bends, crushing, tension and unsupported spans during installation.
- Complete channel continuity and functional testing after the cable is installed.
FAQ
What is 129525-0050-02?
129525-0050-02 is an assembled external termination block cable.
What length is identified by 129525-0050-02?
129525-0050-02 is configured for 50 ft (15 m).
Is 129525-0050-02 a monitoring module?
No. 129525-0050-02 is an interconnect cable used with compatible rack I/O and external termination hardware.
Can 129525-0050-02 be used with internal termination?
No. 129525-0050-02 is intended for an external-termination architecture.
What must be matched before ordering 129525-0050-02?
Confirm the I/O module, terminal block, connectors and required 50 ft route for 129525-0050-02.
What should be tested after installing 129525-0050-02?
Check connector seating, continuity, shielding and channel operation after installing 129525-0050-02.
Recommended Models
| ABB/BBC GJR2242000R1 LR370A-E 9060/035 | KF37 DRS71S4BE05/MM03/TH | GO2209495 A52321004.012XX |
| IR425 / ir425-D4-2 | NXS00455-A2H1SSS-A1A2000000+QGLM+FL23+DPAP+DLDE | 6ES5 470-8MC11 |
| STM34 960901 | 6GK5204-2BC10-2CA2 | 4X575 W 10A |
| 21.60.50FY + 21.60.0001.A | MTN646808 | 901-9648 |
| 1SAZ211201R1035 TA25DU-5.0 | E84AVSCE7514SB0 | SXWSCDXSELXW |
| QUINT-UPS/24DC/24DC/10 | XS821-22 | NHMD-13-14 |
| Schmalz SGM 34 G1/4-IG A3 10.01.17.00090/2 | B3.1/5-PKZ0 | INF-1001 |
| 6SE6440-2AB21-1BA1 | 3VA1163-5MH36-0AA0 | Ve 2424 D/C |
| ABB TU840/3BSE020846R1 | 3RV1363-7EN10 | SLT-16-40-A-CC-B |
| Elfa 566542 EP62B10 | Roemheld 1942201 | 6ES7141-0BF00-0XB0 |


