Bently Nevada 133323-01 Modbus RS485 I/O Module

Bently Nevada 133323-01 Modbus RS485 I/O Module

Item NO.: 133323-01

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameBently Nevada 133323-01 Modbus RS485 I/O Module
  • Item NO.133323-01
  • Weight0.4000 kg = 0.8818 lb = 14.1096 oz
  • CategoryTSI
  • BrandBently Nevada
  • Creation Time2024-12-23
INDUSTRIAL PART RECORD3500/92 Communication Gateway
3500/92 · MODBUS RS485 · REAR COMMUNICATION I/O

Bently Nevada 133323-01 Modbus RS485 I/O Module

The Modbus RS485 rear I/O module for the Bently Nevada 3500/92 Communication Gateway.

ProtocolModbus
Physical interfaceRS485
Companion front136180-01
PRODUCT DOSSIER

Product Profile

01

Bently Nevada 133323-01 is the Modbus RS485 I/O module listed for the 3500/92 Communication Gateway.

The companion front gateway module is 136180-01. The rear I/O selection establishes the physical serial interface and therefore must match the field network rather than a different RS232/RS422 or Ethernet execution.

Gateway replacement should retain the address map, communications settings, cable topology and host-system test record.

PUBLISHED EVIDENCE

Technical Data

02
Manufacturer

Bently Nevada

Exact part number

133323-01

Product family

3500/92 Communication Gateway

Component type

Modbus RS485 I/O Module

Interface

RS485 serial communications

Protocol context

Modbus

Companion front module

136180-01 Communication Gateway Module

Alternative rear I/O

125736-01 RS232/RS422

Ethernet/serial alternatives

136188-01 Ethernet/RS232; 136188-02 Ethernet/RS485

CONTROLLED PATH

System Role

03
1

Export the communication map

Record Modbus address, baud rate, framing, register use and gateway configuration.

2

Trace the serial segment

Capture polarity, shield, termination, biasing and every network node before disturbance.

3

Validate end-to-end exchange

Confirm gateway diagnostics and every required value at the Modbus master after service.

MATCH CRITERIA

Compatibility

04

RS485 field interface

The rear module provides the RS485 physical layer for the associated Modbus gateway.

Paired gateway assembly

133323-01 is recorded with the 136180-01 front communication module.

Variant-controlled selection

Other 3500/92 I/O modules use different serial or Ethernet interfaces.

Configuration traceability

Device address, baud rate, framing and register use belong to the service file.

FIELD DUTY

Applications

05

DCS data exchange

Sending selected 3500 rack data to a Modbus master over an RS485 network.

Legacy serial integration

Maintaining a multi-device serial segment whose electrical interface is already documented.

Gateway spare preparation

Separating the rear RS485 I/O module from other 3500/92 communication variants.

GLOBAL INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact-model records keep 133323-01 traceable

IndustryParts keeps the requested identity, quantity, label evidence and delivery record together so the proposed supply can be checked against the installed application before dispatch.

Label evidence retained
System context reviewed
Dispatch record controlled
IndustryParts industrial automation support
PROCUREMENT QUESTIONS

FAQ

06
Q01

Which front module is paired with 133323-01?

Bently Nevada lists 136180-01 as the 3500/92 Communication Gateway front module.

Q02

What makes 133323-01 different from 125736-01?

133323-01 is the RS485 I/O module, while 125736-01 is the RS232/RS422 rear I/O execution.

Q03

What network details should accompany a 133323-01 enquiry?

Provide the gateway label, node address, baud rate, framing, topology, termination and terminal photographs.

Q04

Should 133323-01 be replaced before the register map is saved?

No. Retain the gateway configuration and the host register map before changing the physical interface hardware.

Q05

What proves 133323-01 is communicating after service?

Require normal gateway status and verified end-to-end values, alarms and quality states at the Modbus master.