Bently Nevada 135031-01 RIM I/O Module with Modem Interface

Bently Nevada 135031-01 RIM I/O Module with Modem Interface

Item NO.: 3787692

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameBently Nevada 135031-01 RIM I/O Module with Modem Interface
  • Item NO.3787692
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryTSI
  • BrandBently Nevada
  • Creation Time2026-10-10
3500/20 RACK INTERFACE | BUILT-IN MODEM | REAR I/O MODULE

Bently Nevada 135031-01 RIM I/O Module with Modem Interface

The modem-interface I/O module used with a Bently Nevada 3500/20 Rack Interface Module.

BrandBently Nevada / Baker Hughes
Model135031-01
Product Type3500/20 RIM I/O Module with Modem Interface
01

Overview

135031-01 is the spare part number for the Bently Nevada 3500/20 Rack Interface Module I/O assembly with a built-in modem interface. It occupies the rear I/O position associated with the rack interface function.

135031-01 must not be confused with 125768-01, which is the alternate 3500/20 I/O module with an RS232/RS422 interface. Confirm the installed interface and host connection before exchange.

02

Specs

Manufacturer Bently Nevada, a Baker Hughes business
Model 135031-01
System 3500 Machinery Protection System
Associated Monitor 3500/20 Rack Interface Module
Product Type RIM I/O module with built-in modem interface
Installation Position Rear I/O position associated with the rack interface module
Documented Alternative 125768-01 RIM I/O module with RS232/RS422 interface
Compatible RIM Context Standard 3500/20 or TMR 3500/20 architecture when configured with modem-interface I/O
RIM Ordering Code for this Interface B = 01, I/O module with built-in modem
Agency Approval Code Defined by the complete 3500/20 ordering string
Service Requirement Exact rack, RIM type, firmware and host communication arrangement must be recorded
Static Handling Grounded ESD handling required
03

Features

  • Provides the documented built-in modem interface for the 3500/20 rack-interface position.
  • Keeps the communications termination separate from the front Rack Interface Module.
  • Supports service replacement without changing the front module when the I/O assembly is the diagnosed item.
  • Uses a distinct spare number to prevent substitution with the RS232/RS422 execution.
04

Applications

  • 3500 racks whose host link uses the built-in modem version of the 3500/20 I/O module.
  • Maintenance of machinery-protection racks in power generation, oil and gas, refining and process plants.
  • Like-for-like replacement after cable, grounding and host communications have been checked.
05

Lifecycle

  • Export the 3500 rack configuration and record RIM firmware before shutdown.
  • Photograph the rear wiring, cable destination and all labels before removal.
  • Confirm whether the installed front RIM is standard or TMR and preserve the complete approval configuration.
  • After exchange, verify rack communications, event time, host data and System 1 or other connected software before returning the rack to service.
06

FAQ

Can 135031-01 replace the RS232/RS422 RIM I/O module?

No automatic substitution should be made. 135031-01 is the built-in modem version; the host interface, cable and rack configuration must match.

What evidence is needed to quote 135031-01 accurately?

Provide photographs of the front RIM and rear I/O labels, rack serial number, firmware, host connection, cable part number and approval markings.

Should the rack configuration be reloaded after replacing 135031-01?

Preserve a current backup and compare the rack configuration after service; any reload must follow the site change procedure and correct firmware baseline.

What should be tested before blaming 135031-01 for a communication loss?

Check rack power, front RIM health, cable continuity, grounding, host port settings, modem path and software communication diagnostics.

How should 135031-01 be commissioned in a running protection system?

Use an approved outage or bypass plan, apply ESD controls and verify communications without defeating active machinery-protection functions.