Bently Nevada 1900/65A-01-01-03-00-00 Equipment Monitor
A 110–220 VAC powered 1900/65A with attached display, fiberglass NEMA 4X/IP66 housing and no communications option.
Technical Summary
1900/65A-01-01-03-00-00 packages the 1900/65A monitor with an external 110–220 VAC, 50/60 Hz supply, an attached display and a fiberglass weatherproof housing with viewing window.
The housing execution changes installation, cable-entry and environmental planning. The final two fields select no agency approvals and no Modbus communications.
Specifications
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Complete Model | 1900/65A-01-01-03-00-00 |
| Power Option | 110 to 220 VAC, 50 to 60 Hz external supply |
| Display Option | Attached display, no cable |
| Mounting Option | Fiberglass NEMA 4X/IP66 housing with window |
| Approval Option | None |
| Communications Option | None |
| Transducer Inputs | 4 configurable channels |
| Temperature Inputs | 4 channels |
| Relay Outputs | 6 |
| Recorder Outputs | 4 × 4–20 mA |
| Operating Temperature | −20 to +70 °C |
Features
- Protects monitoring hardware inside a windowed weatherproof fiberglass enclosure.
- Allows local display viewing while the enclosure remains closed.
- Processes vibration and temperature variables with configurable alarming and relay voting.
- Provides recorder and buffered-output interfaces for plant and service connections.
Compatibility
- Confirm the external AC supply assembly, incoming voltage and protective-device arrangement.
- Review gland positions, cable diameters, grounding and enclosure sealing before installation.
- Retain only supported transducers with their correct power, polarity and scale configuration.
- Plan separate data access because this order code does not include Modbus communications.
Replacement
- Back up configuration and document every field-cable entry before disturbing the enclosure.
- Inspect door gasket, window, glands, grounding and internal supply wiring before reuse.
- Complete a closed-enclosure functional test covering channels, display, recorder outputs, relays and environmental sealing.
FAQ
Why is the housing option important when replacing 1900/65A-01-01-03-00-00?
It determines mounting footprint, cable entry, viewing arrangement and environmental sealing; a bare monitor is not a mechanical replacement for the packaged assembly.
Does 1900/65A-01-01-03-00-00 provide Modbus data?
No. The final 00 field omits communications, so confirm how the existing plant receives status and measurements.
What AC information should accompany a 1900/65A-01-01-03-00-00 enquiry?
Provide actual mains voltage and frequency, supply assembly details, protective device, grounding method and enclosure terminal photographs.
Can the weatherproof enclosure be reused with another 1900/65A option?
Only after checking internal supply, display, mounting, glands, approvals and heat-dissipation requirements against the intended execution.
What configuration assets are required before replacing 1900/65A-01-01-03-00-00?
Save channel definitions, filters, alarms, relay voting, recorder mapping, tags and bypass logic, plus an input-to-terminal schedule.
What final inspection protects the 1900/65A-01-01-03-00-00 installation?
Verify gland sealing, gasket compression, grounding, window condition and closed-door operation after proving all monitoring and trip functions.
Recommended Models
| R901020360 | MASI68 | DM3E-870 |
| NTPS-24-1.3 | R6YXG500200 | 4930275 |
| HWS600-24 | WK4 SL/U/V0 57.504.9055.0 | IC693ALG390G |
| 2CDg510004R0021 | PN16 DN100mm | RCS2-SA6C-I-30-3-400-T2-S |
| LECP6P1D-LEFB16UT-600 | IF672 | CP6410 1SAP541010R0001 |
| CINDY 12-B-DND-G01-S020/060-A-G9-2/G9-2-150150 | Interlogix D7130WDMB | DNC-50-525-PPV-A |
| RM65V-16IBS-I 0821734189 | PC4301 CCL-263 H-7PCRD1254B | Siemens, 3WL1216-3CB42-4AJ2-Z |
| Siemens 6EP1437-2BA00 | Siemens 1FT51021AC711EA0 | 24/24/2-1131 |
| NZMN1-A100 | C98040-A1057-P2-02 | Allen Bradley 1734-IE2C+OB4+IB8 |
| Siemens 6SE7041-1TK60 | ASI2314-B3 | Siemens 1PH7133-2ND02-0LK0 |