Home>TSI>Bently Nevada 21504-000-040-10-02 7200 Series 8 mm Standard-Mount Proximity Probe

Hot Categories

Bently Nevada 21504-000-040-10-02 7200 Series 8 mm Standard-Mount Proximity Probe

Bently Nevada 21504-000-040-10-02 7200 Series 8 mm Standard-Mount Proximity Probe

Item NO.: 3811401

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameBently Nevada 21504-000-040-10-02 7200 Series 8 mm Standard-Mount Proximity Probe
  • Item NO.3811401
  • Weight0.2000 kg = 0.4409 lb = 7.0548 oz
  • CategoryTSI
  • BrandBently Nevada
  • Creation Time2026-10-27
Bently Nevada 21504-000-040-10-02 7200 Series 8 mm Standard-Mount Proximity Probe
7200 SeriesPRODUCT RECORD

LEGACY 7200 SERIES · 8 MM TIP · STANDARD 3/8-24 MOUNT

Bently Nevada 21504-000-040-10-02 7200 Series 8 mm Standard-Mount Proximity Probe

A legacy unarmored 8 mm probe configuration whose case, cable and connector codes must be retained as a single assembly.

Probe styleStandard mount
ArmorNone
Total cable1.0 m
01
PRODUCT CONTEXT

Overview

21504-000-040-10-02 is a legacy 7200 Series 8 mm standard-mount proximity probe. The 21504 base identifies the unarmored 3/8-24 probe style, while the remaining fields preserve its mechanical case, one-metre cable and connector execution.

This probe belongs to a calibrated eddy-current measurement chain. Probe diameter alone does not establish interchangeability; the matching extension cable, Proximitor Sensor, system length and target calibration must be identified from the installed record.

02
CONTROLLED DATA

Specifications

Manufacturer
Bently Nevada
Exact model
21504-000-040-10-02
Legacy platform
7200 Series
Probe tip class
8 mm
Mounting style
Standard mount
Thread
3/8-24 UNF
Armor
Not included on 21504 base
Unthreaded-length field
000
Case-length field
040
Total cable-length field
10 (1.0 m)
Connector field
02, miniature coaxial execution
Measurement principle
Eddy-current proximity
03
FUNCTIONAL PROFILE

Features

A

Unarmored lead

The 21504 base separates this execution from the stainless-steel-armored 21505 family.

B

Legacy inch-thread body

The standard 3/8-24 case must match the machine bracket or housing.

C

One-metre probe lead

The cable-length field remains part of the calibrated total system length.

D

Exact connector execution

The final 02 field must be kept visible during receiving and chain assembly.

IndustryParts industrial automation support
INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact identity before quotation

IndustryParts prepares 21504-000-040-10-02 enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.

Complete labelRevision retainedApplication evidence
04
FIELD USE

Applications

Relative shaft vibration

Sensing shaft-to-bearing-housing motion in a compatible 7200 measurement chain.

Axial position

Measuring static shaft position where the approved range and target geometry are maintained.

Legacy spare control

Holding a like-for-like probe for equipment whose installed chain remains documented as 7200 Series.

05
SERVICE DISCIPLINE

Lifecycle

01

Record

Capture the complete probe, extension-cable and Proximitor labels plus the installed gap voltage.

02

Handle

Protect the unarmored cable and connector from bending, contamination and pulling damage.

03

Validate

Reassemble the correct total system length, gap the probe and verify scale and monitor response.

06
CUSTOMER QUESTIONS

FAQ

Q01

What distinguishes 21504-000-040-10-02 from the 21505 family?

The 21504 base is the unarmored standard-mount probe; 21505 denotes a stainless-steel-armored lead.

Q02

May 21504-000-040-10-02 be selected from the 8 mm tip size alone?

No. Thread, case length, cable length, connector and the remaining 7200 measurement chain must also match.

Q03

Which photographs help qualify 21504-000-040-10-02?

Provide the probe body, connector, extension cable, Proximitor Sensor and mounting location without obscuring any label.

Q04

How should an intermittent 21504-000-040-10-02 signal be investigated?

Check connector cleanliness, cable movement, static gap, extension-cable continuity and monitor diagnostics before replacing hardware.

Q05

What confirms 21504-000-040-10-02 serviceability after installation?

Document the final gap voltage, stable waveform, expected scale response and alarm verification in the host monitor.

ENQUIRY INFORMATION

Send the complete 21504-000-040-10-02 label, requested quantity and destination.

You May Also Like