Bently Nevada 330104-00-14-05-02-00 Armored 3300 XL 8 mm Proximity Probe
A metric armored probe with a 140 mm case and short standard cable for a matched 3300 XL loop.
Overview
330104-00-14-05-02-00 is the armored M10 × 1 execution of the 3300 XL 8 mm proximity probe. The short lead and defined case geometry make it a distinct configuration within the metric probe range.
The flexible stainless-steel armor protects the probe lead, but it also changes routing and clearance requirements. The complete loop must remain matched electrically after any probe exchange.
Specs
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Model | 330104-00-14-05-02-00 |
| Product Family | 3300 XL 8 mm Proximity Transducer System |
| Probe Case Thread | M10 × 1 |
| Cable Armor | Flexible stainless-steel armor with FEP outer jacket |
| Unthreaded Length | 0 mm |
| Overall Case Length | 140 mm |
| Total Probe Length | 0.5 m (1.6 ft) |
| Connector / Cable | Miniature coaxial ClickLoc connector, standard cable |
| Connector Protector | Not included |
| Agency Approval | Not required |
Features
- Measures shaft vibration or position without mechanical contact.
- Adds flexible cable armor for routing protection near the machine.
- Uses a short lead suited to nearby extension-cable connection.
- Maintains the standard 3300 XL electrical system relationship.
Applications
- Machine points exposed to cable abrasion or physical contact.
- Metric threaded radial vibration probes.
- Short-lead installations using a remote extension cable.
Lifecycle
- Inspect armor for crushing, broken coils or jacket damage.
- Support the cable so armor weight does not load the probe connector.
- Retain complete loop identities and baseline gap results.
- Test monitor response after any probe, cable or connector work.
FAQ
What distinguishes 330104-00-14-05-02-00 from 330103 probes?
The 330104 family includes cable armor; verify routing space and termination support rather than treating the bodies as identical.
Can the short lead on 330104-00-14-05-02-00 be extended with any coaxial cable?
No. Use the matching Bently Nevada extension cable and preserve the calibrated system length.
What should be inspected on a used 330104-00-14-05-02-00?
Check the probe tip, thread, armor, jacket, connector and complete label, then evaluate the loop electrically before service.
Which mounting drawing detail matters for 330104-00-14-05-02-00?
Confirm the target location, case engagement, insertion range and bend clearance for the armored lead.
Is 330104-00-14-05-02-00 the approved hazardous-area version?
No approval is selected by the final 00 code; certification requirements must be resolved before ordering.
What acceptance record follows installation of 330104-00-14-05-02-00?
Retain gap voltage, dynamic signal, monitor alarm checks, final routing and connector-condition evidence.
Recommended Models
| PSD01-1501 1027906 | P7-125 | 6NH1804-0AA01-3CB2 |
| 3UG4616-1CR20 | DRE90M4BE2 | TBOX MS-PSTN (I-04) |
| Siemens 6ES5 458-7LA11 | 6NH1802-0BA | RM4 JA31MW 033315 |
| Siemens LFS1.11A2 | ABB CM572-DP 1SAP170200R0001 | ACM8CB |
| QTCU2.5-TWIN | GTH53-2411-A1F1-2Q | DX571 1TNE968902R2302 |
| MHA4-MS1H-3/2G-4-K-SA | ADC 3E02FW | MDD090A-N-030-N2M-110GB1 |
| R166239420 | ATP 990/3 010426 | EXD5314CE |
| LV434010 | A61P | 6ES7 972-0ED00-0XA0 |
| Intel QX82527 | Blum Novotest 184561 EM31 | TSXRAM12816 |
| UP5864/010 0052764 | C40E-1001BH030 | 3SE7160-1AE00 |