Bently Nevada 330162-03-45-45-45-05-05-94-01-02 Dual High-Pressure Feedthrough
A configuration-controlled two-channel signal passage for a 3300 proximity system pressure boundary.
Product Identification
330162-03-45-45-45-05-05-94-01-02 identifies a configured Bently Nevada 3300 XL dual triaxial high-pressure feedthrough assembly. It carries two proximity-system signal paths across a pressure boundary while maintaining the required mechanical seal.
The submitted suffix is retained as one complete legacy configuration. Before replacement, each segment must be checked against the installed nameplate, cable lengths, seal material and mating connectors.
Engineering Data
| Manufacturer | Baker Hughes Bently Nevada |
|---|---|
| Complete Model | 330162-03-45-45-45-05-05-94-01-02 |
| Base Family | 330162 |
| Product Type | Dual triaxial high-pressure feedthrough |
| Signal Paths | Two |
| Compatible Sensor Family | 3300 proximity system |
| Armor Option | Armor at high-pressure end |
| Confirmed Cable Length | 4.5 m high-pressure lead |
| Pressure-Boundary Role | Sealed dual-channel signal passage |
| Configuration Control | Verify the complete legacy suffix at the installed assembly |
Functions
- Routes two triaxial proximity-signal paths through one pressure-boundary assembly.
- Provides armor protection at the high-pressure end in the identified configuration.
- Uses configured lead lengths, seal material and connector choices as part of the complete assembly.
- Supports separation between probe-side and signal-conditioner-side wiring areas.
- Maintains 330162-03-45-45-45-05-05-94-01-02 as one configuration-controlled item rather than a collection of interchangeable suffixes.
Applications
- Dual proximity measurements crossing a compressor or machine pressure boundary.
- High-pressure rotating-equipment installations using 3300 proximity systems.
- Probe wiring that requires separate high-pressure and low-pressure sides.
- Maintenance replacement of a configured dual-channel penetration assembly.
- Machinery-protection loops where seal and connector selection are configuration-critical.
Lifecycle
- Preserve the exact 330162-03-45-45-45-05-05-94-01-02 code in the equipment record.
- Document both channels, probe systems, connector sides and routed lengths.
- Review the pressure-boundary isolation and site permit procedure before removal.
- Inspect sealing surfaces and install the approved seal arrangement.
- Pressure-test the boundary and validate both proximity channels after installation.
FAQ
What is 330162-03-45-45-45-05-05-94-01-02?
330162-03-45-45-45-05-05-94-01-02 is a configured dual triaxial high-pressure feedthrough in the Bently Nevada 330162 family.
How many signal paths does 330162-03-45-45-45-05-05-94-01-02 provide?
330162-03-45-45-45-05-05-94-01-02 carries two proximity-system signal paths.
Does 330162-03-45-45-45-05-05-94-01-02 include armor?
The identifiable armor option in 330162-03-45-45-45-05-05-94-01-02 specifies armor at the high-pressure end.
Can the complete 330162-03-45-45-45-05-05-94-01-02 suffix be shortened when ordering?
No. Retain 330162-03-45-45-45-05-05-94-01-02 in full and verify every configured segment against the installed assembly.
What should be checked before installing 330162-03-45-45-45-05-05-94-01-02?
Check the pressure fitting, seal material, routed lengths, connector genders and both matched proximity systems for 330162-03-45-45-45-05-05-94-01-02.
What tests follow replacement of 330162-03-45-45-45-05-05-94-01-02?
Pressure-test the boundary and validate the static and dynamic signals on both 330162-03-45-45-45-05-05-94-01-02 channels.