Bently Nevada 330854-040-24-05 25 mm Extension Cable
A non-armored 4.0 m high-temperature FluidLoc extension cable with multiple approvals for 25 mm systems.
Overview
330854-040-24-05 is a Bently Nevada extension cable for the 3300 XL 25 mm proximity transducer family. Option 040 defines 4.0 m length, option 24 defines high-temperature FluidLoc cable without armor, and option 05 selects the multiple-approval execution.
The cable supports long-range proximity measurements such as turbine differential expansion when it is combined with the exact compatible probe and Proximitor Sensor. Its approvals apply to the documented loop and installation, not to the cable as an isolated generic item.
Specs
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Model | 330854-040-24-05 |
| Series | 3300 XL 25 mm proximity transducer system |
| Component Type | Extension cable |
| Length | 4.0 m |
| Cable Construction | High-temperature FluidLoc |
| Armor | Without armor under option 24 |
| Approval Option | 05, multiple approvals |
| Nominal System Scale Factor | 0.787 V/mm (20 mV/mil) |
| Nominal System Linear Range | 12.7 mm (500 mil) |
| Primary System Use | Large displacement and differential-expansion measurement |
Features
- Preserves the calibrated electrical path of a 25 mm proximity channel.
- Uses a high-temperature FluidLoc design for demanding turbine-area routing.
- Retains the non-armored option where flexibility and the installed protection method require it.
- Supports approved systems when the associated probe, Proximitor, barriers and wiring follow the applicable documentation.
Applications
- Steam-turbine differential expansion measurement.
- Large axial displacement channels using the 3300 XL 25 mm family.
- Replacement of a damaged 4 m cable in an existing high-temperature approved loop.
Lifecycle
- Confirm option 24 rather than the visually similar armored option 25.
- Review hot-surface clearance, conduit or tray protection and minimum bend radius before routing.
- Retain certificate and barrier records with the full loop bill of materials.
- Validate zero, direction, usable travel and monitor scaling over the required mechanical movement after service.
FAQ
What is the practical difference between option 24 on 330854-040-24-05 and option 25?
Option 24 is the non-armored high-temperature FluidLoc cable; option 25 adds armor, so routing, flexibility and mechanical protection are different.
How is the mating probe selected for 330854-040-24-05?
Use the 25 mm probe length that makes the exact total electrical length required by the installed 25 mm Proximitor Sensor.
Does the 05 approval suffix make any field wiring acceptable for 330854-040-24-05?
No. The complete approved loop, barriers or isolators, grounding, cable parameters and area certificate must all agree.
What commissioning check matters most on a differential-expansion loop using 330854-040-24-05?
Verify mechanical zero, polarity, expected rotor travel, usable electrical range and monitor scaling across the operating movement.
When should 330854-040-24-05 be replaced rather than rerouted?
Replace it if insulation, FluidLoc construction, connector integrity or high-temperature exposure history is compromised; rerouting does not restore damaged cable.
Recommended Models
| MR7402.4842-U3-N60-G01-AK1-M0-P0-S0 | 3RK1304-0HS00-8AA0 | Allen-Bradley 194R-J30-1753S |
| MDX61B0037-2A3-4-00 | V24230-Z6-A2-01 ES01 | 3RT1034-1AP04 |
| 39D1325/160 | AWS-842TPB | Rexroth R072032000 |
| Hager SB399 | SEW R87 DRE90M4BE2/TF | BZMB1-A100 |
| WAGO 2004-1207 | B&R 3DI475.6 | A1X3PK |
| LV429847 | BAU200 | SEW BSHF402/R CMP71M/BP/KY/VR/RH1M/SB1 |
| SE-C4.170.030-14.000 | RVS 12 20.050.82222 | RS485 / rs485 4683-TTM-1F |
| LIP-3ECTB EIA709/IP | L1-130V1-60 | SEW R37 DRS71S4BE05/MM03/MO |
| LQSE-4T10-D | LRS-1/4-D-O-I-MIDI | 21X25-RS0B0-Z0H0-ST5S00N-R0SU |
| 3WE 6 A62/EG24N9K4 R900561189 | AW-HHD100E | Sick C40S-1803CA010 |