Bently Nevada 330901-00-40-10-11-05 3300 XL NSv 4.0 in Case-Length Proximity Probe
An unarmored 3300 XL NSv proximity probe with a 4.0 in case, 1.0 m FluidLoc cable, miniature ClickLoc connector and multiple approvals.
Technical Summary
PRODUCT CONTEXT330901-00-40-10-11-05 is a 3300 XL NSv probe ordered with a 1/4-28 UNF thread and no probe armor. Its 00 field specifies 0.0 in of unthreaded length, while the 04 field identifies the 4.0 in overall case.
The 10 cable code provides 1.0 m of FluidLoc cable. Connector code 11 adds the miniature ClickLoc connector with protector, and approval code 05 completes the multiple-approval execution. These fields govern the mechanical fit and must remain together when a spare is selected.
Specifications
CONTROLLED DATABently Nevada
3300 XL NSv
1/4-28 UNF
Without armor
0.0 in
4.0 in
1.0 m
FluidLoc
Miniature ClickLoc with protector
Multiple Approvals
Features
FUNCTIONAL DISTINCTIONSCompact NSv sensing format
The NSv family is intended for installations that require a small probe tip and controlled mechanical geometry.
Exact case-length control
The 4.0 in case is encoded independently from the unthreaded length.
Fluid-resistant lead construction
The cable field specifies the FluidLoc execution rather than a standard lead.
Protected detachable connection
The miniature ClickLoc connection includes its protector in the ordering identity.
Compatibility
SELECTION BOUNDARIESMatched transducer chain
Use only the approved NSv extension cable and Proximitor Sensor for the installed system.
Mechanical envelope
Confirm 1/4-28 UNF mounting, 4.0 in case length and the available probe approach.
Hazardous-area record
Retain the complete approval marking and site wiring documentation before replacement.
Replacement
SERVICE WORKFLOWDocument
Record 330901-00-40-10-11-05, target material, probe gap, case position and the mating extension-cable label.
Install
Preserve the approved mounting thread, connector protection and cable route without forcing the probe body.
Validate
Confirm gap voltage, signal stability, alarm behavior and the applicable machine-protection test.
FAQ
CUSTOMER DECISION SUPPORTWhat label evidence should accompany a 330901-00-40-10-11-05 enquiry?
Provide the complete probe, extension-cable and Proximitor Sensor labels, plus the mounting location and requested quantity.
Can a different 330901 case length replace 330901-00-40-10-11-05?
Not from family similarity alone. The 4.0 in case controls mechanical reach and must match the installed assembly.
Why does 330901-00-40-10-11-05 retain connector code 11?
Code 11 identifies the miniature ClickLoc connection, connector protector and FluidLoc cable execution.
Which field condition matters before removing 330901-00-40-10-11-05?
Record the running gap voltage, probe position, cable route and connector condition before the measurement chain is opened.
What closes the 330901-00-40-10-11-05 replacement record?
Document correct mechanical fit, stable gap and signal behavior, and completion of the approved machine-protection test.
About IndustryParts
https://www.industryparts.com/Controlled handling for 330901-00-40-10-11-05
IndustryParts keeps the submitted 330901-00-40-10-11-05 identity, requested quantity and installed-system evidence together so a proposed supply can be checked before dispatch.
- Complete submitted model retained
- Installed-system evidence reviewed
- Quotation record kept with the enquiry