Bently Nevada 330901-00-90-10-02-05 NSv Proximity Probe
A long-case 1/4-28 NSv probe with ClickLoc termination and the multiple-approval option.
Product Profile
330901-00-90-10-02-05 is a Bently Nevada 3300 XL NSv probe with a 1/4-28 UNF threaded case, zero unthreaded length and a 9.0-inch overall case. The extended body supports deep-reach mounting arrangements.
Its 1.0 m standard cable uses a miniature coaxial ClickLoc connector without a protector, while the final field selects the multiple-approval execution.
Technical Data
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Complete Model | 330901-00-90-10-02-05 |
| Transducer Family | 3300 XL NSv |
| Case Thread | 1/4-28 UNF-2A |
| Cable Armor | Without armor |
| Unthreaded Length | 0.0 in |
| Overall Case Length | 9.0 in |
| Total Probe Length | 1.0 m |
| Connector | Miniature coaxial ClickLoc |
| Approval Option | Multiple approvals |
System Role
- Senses relative shaft vibration or position where small target areas or restricted clearances favor the NSv system.
- Provides long threaded reach for machinery housings with deep probe mounting.
- Forms one calibrated chain with the matching NSv extension cable and Proximitor Sensor.
Compatibility
- Control insertion depth, straightness and thread engagement for the 9.0-inch case.
- Match probe and extension-cable lengths to the selected NSv Proximitor Sensor.
- Verify target material, mechanical gap and channel scaling before commissioning.
- Keep the multiple-approval documentation with every associated loop component.
Applications
- Deep-reach compressor or turbine probe locations.
- Small-shaft vibration and position measurement.
- Speed or phase-reference loops engineered for the NSv transducer system.
FAQ
What installation risk is highest for 330901-00-90-10-02-05?
The long case increases sensitivity to insertion depth, straightness, thread support and clearance behind the mounting point.
Can 330901-00-90-10-02-05 use an arbitrary extension-cable length?
No. Probe and extension-cable lengths must total the selected NSv Proximitor Sensor system length.
Does the 05 suffix make every 330901-00-90-10-02-05 installation compliant?
No. The complete loop, barriers, wiring and installation drawing must satisfy the site classification.
What data should be captured before replacing 330901-00-90-10-02-05?
Record gap voltage, insertion depth, extension-cable code, Proximitor Sensor code, monitor channel and target material.
Can 330901-00-90-10-02-05 be substituted by a shorter-case NSv probe?
Only after the holder, insertion depth, thread engagement and cable routing are re-engineered and documented.
What acceptance checks are appropriate for 330901-00-90-10-02-05?
Verify static gap, signal polarity, runout, channel scaling, alarm behavior and mechanical clearance throughout operation.
Recommended Models
| MGFAS2-DSM-SNI-B/ECR | PCI-733 190976C-04 | 82L25-103B800 |
| 8L501-101 | LI30-60D | 16DI ITEM3-2000U016000 |
| 1FT6064-1AF71-4EH1 | BWL000F 4040D-R011-S49 | 6ES5254-4UB21 |
| AFB3-6 14040137 | HD Link Pro 3D | 1TNE968902R2301 |
| USB32DVIPRO | PSD01-1501 1027906 | SLA-440-ALER |
| 6AG1055-1MB00-2XB1 | 24BS24AD4E | 4000-68522-4391001 |
| 30-60/48 | FMZ5000 904093 | 501MA |
| Rofin 101 115 550 | MOFH-3-1/8 | SVS-4-1/8 |
| apbt320 | 091447 | 3IF762.9 |
| Siemens 6ES5700-8FA11 | Alco XB 1019RW55-1B | 6SN1112-1AC01-0AA0 |