Bently Nevada 330903-00-07-10-01-00 NSv Proximity Probe
An M8×1 narrow-side-view probe with a 70 mm case, 1.0 m standard cable and protected ClickLoc connector.
Technical Summary
330903-00-07-10-01-00 is a metric 3300 XL NSv proximity probe for installations where counterbore, side-view or rear-view clearance limits a standard probe arrangement.
Its ordering code identifies an M8×1 case without armor, zero unthreaded length, 70 mm overall case length, 1.0 m total probe length and a standard cable with connector protector.
Specifications
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Complete Model | 330903-00-07-10-01-00 |
| Probe Family | 3300 XL NSv |
| Case Thread | M8×1 |
| Armor | Without armor |
| Unthreaded Length | 0 mm |
| Overall Case Length | 70 mm |
| Total Probe Length | 1.0 m |
| Connector / Cable | ClickLoc with protector, standard cable |
| Agency Approval Option | Not required |
Features
- Provides non-contact eddy-current measurement in restricted mounting spaces.
- Works as one component of a matched NSv probe, extension cable and Proximitor Sensor system.
- Supports radial vibration, axial position, speed and phase-reference applications when configured for the measurement.
- Uses a narrow-side-view geometry intended for small targets and constrained probe access.
Compatibility
- Combine probe and extension cable lengths to match the selected 5 m or 7 m NSv Proximitor system.
- Use the documented NSv extension cable and Proximitor Sensor rather than components from another probe family.
- Check target material, shaft diameter, tip spacing and counterbore clearance against the application limits.
- Protect the ClickLoc connection and observe the minimum cable bend radius.
Replacement
- Record the installed extension-cable and Proximitor numbers before changing 330903-00-07-10-01-00.
- Verify probe gap voltage and channel scaling after replacement; do not compensate for a degraded transducer by recalibration.
- Inspect the mounting thread and avoid excessive thread engagement that could bind the probe case.
FAQ
Can 330903-00-07-10-01-00 be used with a standard 3300 XL 8 mm Proximitor?
No. The NSv probe belongs to the 3300 XL NSv system and must be matched with the corresponding NSv extension cable and Proximitor Sensor.
What should be checked before installing 330903-00-07-10-01-00 in an existing hole?
Confirm the M8×1 thread, available case depth, target geometry, counterbore clearance and maximum permitted thread engagement.
How is the correct NSv system length selected for 330903-00-07-10-01-00?
Add the probe length and extension-cable length, then match that total to the selected 5 m or 7 m Proximitor system.
What commissioning check matters most after replacing 330903-00-07-10-01-00?
Verify mechanical gap, gap voltage, waveform quality, channel scaling and alarm behavior under the site-approved test procedure.
Can a changed scale factor on 330903-00-07-10-01-00 be corrected by field calibration?
A degraded eddy-current component should be replaced; field adjustment can conceal a measurement problem rather than restore system integrity.
Recommended Models
| 5363 EV45 | 6SE6400-3TC01-0BD3 | CT6500 |
| E84DGFCTAJP | E0002181 | 2231 / 2231P |
| LA-165 | MK7850N.82/500/61 | 19F30-SVMB0-A28N-ST6S00N-R0SU |
| FC-102P30KT4E21H1XGXXXXSXXXXA0BXCXXXXD0 | 6FL43013CA11 | X20TB1E |
| AZM 161 B ST2-AS | U12 | RF27 DT80N4/BMG/TF/MSW/ASV1 |
| SLT-6-10-P-A 170549 | C2NI/INETI-CB-WT | SEW KA39 CM3C80S-30A-P/BZ/PK/AK0H/SB1 |
| D-78120 | 787-601 | F73G-KIT-BD002 |
| 3RI350.6 | 6ES5312-5CA12 | AHGD2V113H |
| ABB T3N250 | S22761-L312-B2 | AC2410 |
| 1606-XLS480EE | 1794-PS3 | ABB DO561 1TNE968902R2201 |