Bently Nevada 3500/15-05-05-01 Dual Universal AC Power Supply Configuration
A dual-supply 3500 rack configuration with universal AC modules in both slots and CSA/NRTL/C approval selection.
Overview
3500/15-05-05-01 specifies a Bently Nevada 3500/15 rack power arrangement with a universal AC supply in both the top and bottom slots. The final 01 code selects CSA/NRTL/C Class I, Division 2 approval.
Each installed supply can power a full 3500 rack. In a two-supply arrangement the lower module acts as primary and the upper module acts as backup, allowing either supply to be removed or inserted without interrupting the rack while the other supply remains installed.
Specs
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Configuration | 3500/15-05-05-01 |
| Product Family | 3500 Series Machinery Protection System |
| Top-slot Supply | Universal AC voltage, code 05 |
| Bottom-slot Supply | Universal AC voltage, code 05 |
| Agency Approval | CSA/NRTL/C, Class I, Division 2, code 01 |
| Nominal AC Input | 110 to 220 Vac |
| Non-hazardous Input Range | 85 to 264 Vac rms |
| Hazardous-area Input Range | 85 to 250 Vac rms |
| Input Frequency | 47 to 63 Hz |
| Full-rack Current Draw | 2.8 A rms maximum for universal AC |
| Supply-module Dimensions | 120.7 × 50.8 × 251.5 mm |
| Supply-module Weight | 1.39 kg each |
| Power-input-module Dimensions | 120.7 × 25.4 × 114.3 mm |
| Power-input-module Weight | 0.34 kg each |
| Operating Temperature | -30 to +65 °C |
| Storage Temperature | -40 to +85 °C |
| Humidity | 95%, non-condensing |
Features
- Two universal AC supplies provide a redundant rack-power arrangement.
- The lower slot operates as primary and the upper slot as backup.
- Either supply can individually power the complete rack.
- A Supply OK LED indicates correct operation on each power-supply module.
- No minimum rack load is required.
Applications
- 3500 machinery-protection racks that require redundant universal AC power.
- Installations using nominal 110 to 220 Vac across the documented wide input range.
- Class I, Division 2 rack configurations using the selected CSA/NRTL/C option.
- Maintenance arrangements where one supply must remain available during removal of the other.
Lifecycle
- Keep the complete 3500/15-05-05-01 configuration because both 05 supply positions and the 01 approval suffix are significant.
- Pair each universal AC supply with the compatible universal AC Power Input Module.
- Do not mix the universal AC supply and PIM with legacy high-voltage or low-voltage AC units.
- Verify rack wiring, input voltage and both Supply OK indicators after replacement.
- A single installed supply can power the rack, but redundancy requires both configured supplies to remain serviceable.
FAQ
How many power supplies are specified by 3500/15-05-05-01?
3500/15-05-05-01 specifies two universal AC supplies, one in the top slot and one in the bottom slot.
Which supply is primary in 3500/15-05-05-01?
The lower supply is primary and the upper supply is the backup.
What input range applies to 3500/15-05-05-01?
The universal AC option accepts 85 to 264 Vac rms in non-hazardous areas and 85 to 250 Vac rms in hazardous areas.
Can one 3500/15-05-05-01 supply power the full rack?
Yes. Either supply can individually power the complete 3500 rack.
Can a universal AC supply be mixed with a legacy AC PIM?
No. The universal AC supply and PIM are not compatible with the legacy high-voltage or low-voltage AC units.
What approval is selected by 3500/15-05-05-01?
The final 01 code selects CSA/NRTL/C Class I, Division 2 approval.
Recommended Models
| MR380 | TXM1.8D | H425 |
| ABB 6127/01-83-500 | 1606-XLBUFFER | SWS-N04-S1 |
| MC7004-PUCDCQHA80R | CP-DSKCH-7925G | PB21A30004000 |
| 73091C | C4-DIN-8ESW-E | DM3110 |
| XALD101H29 | ES1018 | UCL-16DI.DI |
| TR-LK/500cc | Ddng485 | IS23DI0XCD000 |
| ABB AX522 / 1SAP250000R0001 | 415cd40 | 60-540-61 |
| SMC-50-LCLC | LG9 | NZMN1-A100 |
| OP10GENR | QD3900H1 | IC200MDL750J |
| GV-U6E | NP08ZL | 2860785 |