Home>TSI>Bently Nevada 3500/20 Rack Interface Module

Hot Categories

Bently Nevada 3500/20 Rack Interface Module

Bently Nevada 3500/20 Rack Interface Module

Item NO.: 3426754

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameBently Nevada 3500/20 Rack Interface Module
  • Item NO.3426754
  • Weight0.9100 kg = 2.0062 lb = 32.0993 oz
  • CategoryTSI
  • BrandBently Nevada
  • Creation Time2025-10-31
SLOT 1 RACK INTERFACE · CONFIGURATION AND DATA ACCESS · 38.4 KBAUD

Bently Nevada 3500/20 Rack Interface Module

The primary configuration and machinery-information interface for a 3500 rack, installed in slot 1 beside the power supplies.

SYSTEM FAMILY3500 Machinery Protection SystemIdentity / integration / lifecycle
01
ASSET RECORD

Product Identification

Bently Nevada 3500/20 is the Rack Interface Module for the 3500 system. It uses the Bently Nevada proprietary protocol to configure the rack and retrieve machinery information and must be installed in slot 1 next to the power supplies.

One RIM is required per rack. The standard module supports normal monitoring applications, while TMR systems require the TMR RIM execution with monitor-channel comparison.

The RIM provides rack-level functions but is not part of the critical monitoring path. I/O choice, communications standard, rack address, configuration key state and host cabling define the installed interface.

02
PUBLISHED DATASET

Engineering Data

Manufacturer

Bently Nevada

Exact product

3500/20

Product type

Rack Interface Module

Required position

Rack slot 1

Quantity

One RIM per rack

Typical power consumption

4.75 W

Front communication

RS232, 38.4 kbaud maximum

Rear I/O communication

RS232/RS422 or internal modem, by I/O option

Protocol

Bently Nevada proprietary

Rack addresses

63 selectable addresses

Operating temperature

−30 to +65 °C for RIM and RS232/RS422 I/O

Storage temperature

−40 to +85 °C

Humidity

95%, noncondensing

Rack space

One full-height front slot plus matched rear I/O slot

03
OPERATING ROLE

Functions

01

Rack configuration gateway

Provides local and remote access for rack configuration and machinery information.

02

System-level controls

Supports rack reset, Trip Multiply, alarm inhibit and configuration key control.

03

Communication routing

Works with RS232/RS422, modem or data-manager I/O variants and compatible external processors.

04

TMR comparison option

The TMR version compares three monitor outputs and records an event when one departs from the configured tolerance.

04
SYSTEM PLACEMENT

Applications

Standard 3500 rack interface

Primary host and configuration connection for a conventional machinery-protection rack.

TMR rack supervision

Monitor comparison and voting support when the TMR RIM execution is selected.

Legacy communications integration

Connection to compatible TDXnet, TDIX or DDIX external processors.

05
MAINTENANCE CONTROL

Lifecycle

01
Capture

Record 3500/20 order option, rack address, front and rear modules, key position, host software and cable type.

02
Control

Archive the rack configuration and exchange the RIM with its correct I/O module under the approved procedure.

03
Prove

Verify CONFIG OK, TX/RX, rack address, host access, alarm/reset contacts and all system events.

EXACT-MODEL INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

Traceable handling for 3500/20

IndustryParts keeps the submitted 3500/20 identity, requested quantity and installed-system evidence together so the proposed supply can be checked before dispatch.

Suffix and release kept visible

Installed role documented

Dispatch check tied to the enquiry

IndustryParts industrial automation support
07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

Where must 3500/20 be installed?

It belongs in slot 1 of the 3500 rack, immediately beside the power supplies.

Q02

Does 3500/20 participate in the critical monitoring path?

No. It provides rack-wide interface functions but the manufacturer states it does not affect normal operation of the critical monitoring path.

Q03

When is the TMR version of 3500/20 required?

Use the TMR RIM for a Triple Modular Redundant 3500 configuration that requires monitor-channel comparison.

Q04

What should accompany a 3500/20 enquiry?

Send the full order code, main and rear I/O labels, rack address, communications type, host software, cable records and rack configuration backup.

Q05

How is 3500/20 accepted after replacement?

Confirm valid configuration, host communication, correct address, reset and inhibit functions, OK relay behavior and event logging.

You May Also Like