Bently Nevada 3500/42M 128229-01 Internal-Termination Proximitor/Seismic I/O Module
A four-channel rear signal-interface module for the 3500/42M monitor with internal field termination.
Technical Summary
3500/42M 128229-01 is a Bently Nevada 3500/42M Proximitor/Seismic I/O Module with internal terminations. It provides the rear signal interface for the four-channel monitor and its supported proximity or seismic transducer inputs.
Field conductors terminate at the rack-side module, keeping the complete signal interface within the 3500 rack assembly.
Specifications
| Manufacturer | Baker Hughes Bently Nevada |
|---|---|
| Complete Model | 3500/42M 128229-01 |
| Catalog Number | 128229-01 |
| Product Family | 3500 Machinery Protection System |
| Module Type | Proximitor/Seismic I/O Module |
| Termination Style | Internal terminations |
| Channel Association | Four-channel 3500/42M monitor |
| Primary Intended Transducer | Seismoprobe transducer |
| Additional Supported Inputs | Proximity, accelerometer and Velomitor inputs with application restrictions |
| Rack Location | Rear I/O position behind the associated monitor |
Features
- Provides the internal termination interface for four 3500/42M measurement channels.
- Accepts the transducer connections supported by the paired Proximitor/Seismic Monitor.
- Keeps channel wiring aligned with the measurement functions configured in channel pairs.
- Places terminal points directly at the rear of the rack.
- Maintains a dedicated rear-module relationship with the associated front monitor.
Compatibility
- 3500/42M 128229-01 is intended for the Bently Nevada 3500/42M four-channel Proximitor/Seismic Monitor.
- Seismoprobe is the primary intended transducer; other supported sensor types require measurement-application review.
- The configured measurement function, transducer scale and signal polarity must match the rack configuration.
- Do not attach an external termination block to this internal-termination module.
- Confirm rack slot, monitor revision and field connector arrangement before installation.
Replacement
- Retain the full 3500/42M 128229-01 part number and its internal termination definition.
- Document all four channel assignments, transducer types and measurement functions before removal.
- Transfer field conductors only after recording every rack terminal position.
- Restore the saved rack configuration without changing ranges or alarm setpoints unintentionally.
- Verify channel OK status, measured values and alarm behavior before returning protection to service.
FAQ
What is 3500/42M 128229-01?
3500/42M 128229-01 is the internal-termination rear I/O module for a 3500/42M Proximitor/Seismic Monitor.
How many channels are associated with 3500/42M 128229-01?
3500/42M 128229-01 interfaces the four channels of the paired monitor.
Which transducer is primarily intended for 3500/42M 128229-01?
The documented primary intended transducer for 3500/42M 128229-01 is Seismoprobe.
Can 3500/42M 128229-01 use external termination blocks?
No. 3500/42M 128229-01 is the internal-termination version.
Where is 3500/42M 128229-01 installed?
3500/42M 128229-01 occupies the rear I/O position behind the associated 3500/42M monitor.
What must be recorded before replacing 3500/42M 128229-01?
Record the four channel assignments, transducer types, polarity and configured measurement functions used with 3500/42M 128229-01.
Recommended Models
| 1LE1003-1DA29-0JB4-Z | Herion 08035 25 | SLT-20-200-P-A |
| ABB 1TNE968900R0100 PM554 | F100S131CIAZGZZZZ | 4G-AE010-R / 07-1144-01 |
| SQ121B6220 120BA220 | Extron 70-464-11 AAP (2)FIB SC | ADVU-32-80-A-P-A |
| G50BH145MVCK3C | BNI0087 | RFX9400 |
| ARI 310 C-3031 | 3HAC17484-10/03 | DDRC420FR |
| 6ES7 142-0BF01-0XB0 | CEM-M2-C60-PZ-SE-161320 | MTN647595 |
| 9130-003-00 | DMC-C 6504086 | CNX-B12W 6001429 |
| Honeywell 5894PI | XL50-ACC3 | RI11/4EDX1/2CF |
| STS 4-TWIN | 1FK7085-7AF71-1FG0 | PIB01CB23500MA |
| 74-115968-04 TTC5-09 | GHG1372041C4996A2701 | HMC490 C100 |