Home>TSI>Bently Nevada 3500/92-04-01-01 Ethernet/RS485 Communication Gateway

Hot Categories

Bently Nevada 3500/92-04-01-01 Ethernet/RS485 Communication Gateway

Bently Nevada 3500/92-04-01-01 Ethernet/RS485 Communication Gateway

Item NO.: 3764589

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameBently Nevada 3500/92-04-01-01 Ethernet/RS485 Communication Gateway
  • Item NO.3764589
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryTSI
  • BrandBently Nevada
  • Creation Time2026-09-08
3500 machinery protection | Ethernet and RS485 gateway

Bently Nevada 3500/92-04-01-01 Ethernet/RS485 Communication Gateway

A 3500 communication gateway with Ethernet/RS485 Modbus I/O, low-memory option and CSA/NRTL/C approval.

BrandBently Nevada
Model3500/92-04-01-01
Product Type3500/92 Ethernet/RS485 Modbus Communication Gateway
01

Key Information

3500/92-04-01-01 is a Bently Nevada 3500/92 Communication Gateway configuration. Code 04 selects the Ethernet/RS485 Modbus I/O module, code 01 selects low memory and the final 01 selects CSA/NRTL/C approval.

The gateway collects monitored values, timestamps, module states and alarm states from the 3500 rack and makes selected information available to process-control or automation systems through Ethernet or serial communications.

02

Functions

  • Communicates by Modbus/TCP over 10BASE-T Ethernet.
  • Supports Modbus RTU communication through the RS485 I/O interface.
  • Exchanges configuration and acquisition data using the Bently Nevada host protocol over Ethernet TCP/IP.
  • Collects rack data across the high-speed internal network with an update time not exceeding one second.
  • Provides OK and TX/RX front-panel status indication.
03

Specifications

Manufacturer Bently Nevada, a Baker Hughes business
Configuration 3500/92-04-01-01
Product Family 3500/92 Communication Gateway
I/O Module Option 04, Ethernet/RS485 Modbus
Memory Option 01, low memory
Agency Approval Option 01, CSA/NRTL/C
Ethernet Interface 10BASE-T, RJ45
Ethernet Protocols TCP/IP, Modbus/TCP and Bently Nevada host protocol
Serial Protocol Modbus RTU over RS485
Rack Data Update Not more than 1 second
Power Consumption 5.6 W typical with RS485 I/O module
Operating Temperature -30 to +65 °C
Storage Temperature -40 to +85 °C
Humidity 95%, non-condensing
04

Installation

  • Reserve one full-height front slot and one full-height rear slot in the 3500 rack.
  • Use shielded Category 5 cabling with RJ45 connectors for the 10BASE-T Ethernet connection.
  • Engineer the RS485 cable run, termination and host interface for the selected Modbus network.
  • Configure the Modbus map and communication parameters in 3500 Rack Configuration Software.
  • Check I/O-module firmware compatibility when combining a newer I/O module with an older gateway main board.
05

Lifecycle

  • Retain the full 3500/92-04-01-01 code because the I/O, memory and approval positions define the gateway configuration.
  • Back up the Modbus register map, serial settings, IP information and rack configuration before replacement.
  • Record the RS485 cable topology and termination arrangement for recommissioning.
  • Confirm firmware compatibility when replacing only the gateway I/O module.
  • Verify process-control data mapping and alarm/status exchange after service.
07

FAQ

Which I/O interface is selected by 3500/92-04-01-01?

3500/92-04-01-01 uses option 04, the Ethernet/RS485 Modbus I/O module.

Does 3500/92-04-01-01 support Modbus/TCP?

Yes. 3500/92-04-01-01 supports Modbus/TCP over its 10 Mbps 10BASE-T Ethernet interface.

Which serial protocol is available on 3500/92-04-01-01?

3500/92-04-01-01 supports Modbus RTU communication through the RS485 interface.

What memory and approval options are coded in 3500/92-04-01-01?

3500/92-04-01-01 uses low-memory option 01 and CSA/NRTL/C approval option 01.

How quickly does 3500/92-04-01-01 collect rack information?

The rack data collection time for 3500/92-04-01-01 depends on configuration but does not exceed one second for all modules in the rack.

What should be backed up before replacing 3500/92-04-01-01?

Save the rack configuration, Modbus map, serial parameters, IP settings and connected-system mapping before replacing 3500/92-04-01-01.