Bently Nevada 60R/PIM01-02-0 Orbit 60 Power Input Module
A 3U Orbit 60 power-interface module with the multi-approval selection and standard no-SIL execution.
Product Profile
60R/PIM01-02-0 is the Power Input Module for an Orbit 60 3U chassis. The 02 field selects the multi-approval execution, and the final 0 selects no SIL option.
Orbit 60 packaged chassis use two PIM modules to support the documented dual-input arrangement. The 3U and 6U versions are chassis-specific and must not be interchanged.
Technical Data
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Complete Model | 60R/PIM01-02-0 |
| Product Family | Orbit 60 Series |
| Module Type | Power Input Module |
| Chassis Compatibility | 3U Orbit 60 chassis |
| Packaged-Chassis Quantity | Two modules |
| Approval Selection | Multi: CSA, ATEX and IECEx |
| SIL Selection | No SIL |
| Interchange Boundary | Not interchangeable with 6U PIM |
System Role
- Forms the documented DC power-entry interface for the 3U chassis.
- Supports the dual power-input architecture when paired as specified in a packaged chassis.
- Keeps chassis power hardware separate from the processor, input and communication modules.
Compatibility
- Match only to the 3U Orbit 60 chassis and its specified power supplies.
- Retain the complete approval suffix and verify both installed PIM labels.
- Confirm supply polarity, grounding, protective devices and the cabinet power-distribution drawing.
Applications
- Service replacement in 3U Orbit 60 machinery-protection racks.
- Maintenance of redundant DC input paths.
- Power-interface verification during chassis retrofit or expansion.
FAQ
Can 60R/PIM01-02-0 be used in a 6U Orbit 60 chassis?
No. The official ordering guidance states that 3U and 6U PIMs and their associated supplies are chassis-specific.
Why are two PIMs often present with 60R/PIM01-02-0?
An Orbit 60 packaged chassis includes two Power Input Modules for its dual-input power architecture.
What does the 02 field mean for 60R/PIM01-02-0?
It selects the multi-approval execution covering CSA, ATEX and IECEx within the Orbit 60 ordering structure.
What should be supplied for a 60R/PIM01-02-0 quotation?
Provide the complete chassis code, both PIM labels, power-supply labels, DC source details and cabinet power drawing.
Can only one power path be tested after replacing 60R/PIM01-02-0?
Both documented input paths, module status and loss-of-source behavior should be verified before the protection system is released.
What installation checks protect 60R/PIM01-02-0?
Confirm chassis size, slot position, polarity, grounding, protective devices, connector condition and adequate cabinet cooling.
Recommended Models
| VPC210 | B110LP | MFD01 |
| KSM303500SP30 | HT9610P0100 | IN1606 |
| 5365EWP01 | Rkc4.221t-30 | HCW2GUS |
| S4-34895 | 8-2MBD | HFRC-01C |
| SEW WH37 CMP50S/BK/KY/AK0H/SB1 | NS-LXMM-A-400-20-2250-T2-N-AQ-L-NT1-RT | DSBC-40-50-PPSA-N3 |
| 6ES7137-6BD00-0BA0 | 3RV1041-4FA10 | FTW 913 K D3 |
| 8BAC0122.000-1 | BNS00A2 | 035 62 SCS |
| BF-50 | EV100 | 3IF672.9 |
| Legrand 574644 | LP-100S/4 S24V5 G830910 | ABB ACS607-0140-3 |
| FEX-40D-AMEU | 13I34-S20P2-T0D0-STBF10N-P0SU | 1071/7 |