Home>TSI>Bently Nevada 60R/SIM01-00-00 Orbit 60 System Interface Module

Hot Categories

Bently Nevada 60R/SIM01-00-00 Orbit 60 System Interface Module

Bently Nevada 60R/SIM01-00-00 Orbit 60 System Interface Module

Item NO.: 3776823

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameBently Nevada 60R/SIM01-00-00 Orbit 60 System Interface Module
  • Item NO.3776823
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryTSI
  • BrandBently Nevada
  • Creation Time2026-09-22
ORBIT 60 | SYSTEM INTERFACE MODULE | STANDARD APPROVAL EXECUTION

Bently Nevada 60R/SIM01-00-00 Orbit 60 System Interface Module

The single Orbit 60 system access module for configuration, diagnostics, controls and external communications.

BrandBently Nevada
Model60R/SIM01-00-00
Product TypeOrbit 60 System Interface Module
01

Overview

60R/SIM01-00-00 is an Orbit 60 System Interface Module configured without hazardous-area certification and without a SIL option. One SIM is required for an Orbit 60 system, including a system that bridges multiple chassis.

The module is the configuration and maintenance access point. It communicates with Orbit Studio, distributes system configuration and provides physical controls used to secure configuration changes.

02

Specs

Manufacturer Bently Nevada, a Baker Hughes business
Complete Model 60R/SIM01-00-00
Product Family Orbit 60 Series
Module Type System Interface Module
System Quantity One per Orbit 60 system
Slot Use One chassis slot
Required Position Adjacent to the Power Input Module
Ethernet Ports Three independently configurable ports
Hazardous-Area Option None
SIL Option None required for the SIM
03

Features

  • Provides access to protection configuration, system-level diagnostics, event lists and firmware maintenance.
  • Supports RUN/PROG control, trip multiply, alarm inhibit, system reset and the protection-fault relay function.
  • Uses a key-lock switch and a utility-side contact to control configuration access.
  • Allows its Ethernet ports to be assigned for configuration, time synchronization, troubleshooting or an external display.
04

Applications

  • Orbit 60 configuration and maintenance access.
  • System-level event, diagnostic and control management.
  • External display and engineering-network connection within the documented architecture.
05

Lifecycle

  • Back up the Orbit Studio project and record all three port assignments before exchange.
  • Preserve key-switch state, security wiring and the protection-fault relay connection.
  • After replacement, confirm module adjacency, system recognition, configuration transfer, time synchronization and every enabled system control.
06

FAQ

Can an Orbit 60 system operate with two 60R/SIM01-00-00 modules?

The documented architecture requires a single SIM for the entire system, even when several chassis are joined through bridge modules.

Why must 60R/SIM01-00-00 be installed next to the PIM?

The SIM has a defined chassis location adjacent to the Power Input Module; the slot map should be preserved during replacement.

Does 60R/SIM01-00-00 provide a SIL selection?

This exact code uses the standard no-SIL suffix, and the official ordering guidance states that SIM certification is not required for an Orbit 60 safety system.

What network information is needed before ordering 60R/SIM01-00-00?

Provide the three port uses, IP settings, time source, external-display connection and the Orbit Studio project version.

What access-security checks apply after fitting 60R/SIM01-00-00?

Verify the key-lock switch, utility-side security contact and the intended ability to enter or block configuration mode.

What acceptance tests should follow a 60R/SIM01-00-00 exchange?

Confirm configuration distribution, diagnostics, alarms, event lists, system controls, Ethernet access and the protection-fault relay path.

You May Also Like