Bently Nevada 60R/SIM01-00-00 Orbit 60 System Interface Module
The single Orbit 60 system access module for configuration, diagnostics, controls and external communications.
Overview
60R/SIM01-00-00 is an Orbit 60 System Interface Module configured without hazardous-area certification and without a SIL option. One SIM is required for an Orbit 60 system, including a system that bridges multiple chassis.
The module is the configuration and maintenance access point. It communicates with Orbit Studio, distributes system configuration and provides physical controls used to secure configuration changes.
Specs
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Complete Model | 60R/SIM01-00-00 |
| Product Family | Orbit 60 Series |
| Module Type | System Interface Module |
| System Quantity | One per Orbit 60 system |
| Slot Use | One chassis slot |
| Required Position | Adjacent to the Power Input Module |
| Ethernet Ports | Three independently configurable ports |
| Hazardous-Area Option | None |
| SIL Option | None required for the SIM |
Features
- Provides access to protection configuration, system-level diagnostics, event lists and firmware maintenance.
- Supports RUN/PROG control, trip multiply, alarm inhibit, system reset and the protection-fault relay function.
- Uses a key-lock switch and a utility-side contact to control configuration access.
- Allows its Ethernet ports to be assigned for configuration, time synchronization, troubleshooting or an external display.
Applications
- Orbit 60 configuration and maintenance access.
- System-level event, diagnostic and control management.
- External display and engineering-network connection within the documented architecture.
Lifecycle
- Back up the Orbit Studio project and record all three port assignments before exchange.
- Preserve key-switch state, security wiring and the protection-fault relay connection.
- After replacement, confirm module adjacency, system recognition, configuration transfer, time synchronization and every enabled system control.
FAQ
Can an Orbit 60 system operate with two 60R/SIM01-00-00 modules?
The documented architecture requires a single SIM for the entire system, even when several chassis are joined through bridge modules.
Why must 60R/SIM01-00-00 be installed next to the PIM?
The SIM has a defined chassis location adjacent to the Power Input Module; the slot map should be preserved during replacement.
Does 60R/SIM01-00-00 provide a SIL selection?
This exact code uses the standard no-SIL suffix, and the official ordering guidance states that SIM certification is not required for an Orbit 60 safety system.
What network information is needed before ordering 60R/SIM01-00-00?
Provide the three port uses, IP settings, time source, external-display connection and the Orbit Studio project version.
What access-security checks apply after fitting 60R/SIM01-00-00?
Verify the key-lock switch, utility-side security contact and the intended ability to enter or block configuration mode.
What acceptance tests should follow a 60R/SIM01-00-00 exchange?
Confirm configuration distribution, diagnostics, alarms, event lists, system controls, Ethernet access and the protection-fault relay path.
Recommended Models
| 3D-A5120 | 5SY6110-6 | LN9602 |
| 6SE7027-2ED61-Z | S-60 | ED706USFM140 + K513SG0240ED706U |
| 3RM1207-1AA04 | FGSE750-21 | OCM-DPR-85-PD-ST-ACV |
| KM 35/2/0225 | X20IF1063-1 | 6EM3105-0C |
| CX2500-0070 | DSBC-50-125-PPVA-N3 | PA-699-04-V |
| PS3050 | G50BB124MHAK2C00 | 360G2-CRT12C-SM-PT |
| 9537440000 | E20 87A658 | X20CP3484-1 |
| R20G04C/N | Gamma 120-ASH-40AT10-E-240-1300-1850-AZ6-S-8NS19-34NS20-1 | Legrand 077662L |
| JBBS-25-E413 | 1794-0B16EPXT | JL669A JL669-61001 |
| 9251/02-40 | Accumet AB15 | DR00060U F05F07-N-DS-17 |