Bently Nevada 9200-01-02-02-00 Seismoprobe Velocity Transducer
A side-connector moving-coil velocity transducer calibrated for horizontal mounting on a circular stud base.
Product Overview
9200-01-02-02-00 is a two-wire moving-coil Seismoprobe that measures absolute vibration of a bearing housing, machine casing or structure. The 01 option defines the calibrated mounting orientation and low-frequency limit.
The remaining code specifies a side-mounted connector, a circular base with a 1/4-28 UNF stud and no agency-approval option. The transducer is self-generating and does not use a proximity-sensor driver.
Performance
- Produces a voltage output proportional to casing vibration velocity.
- Supports continuous monitoring or diagnostic measurement through a compatible high-impedance input.
- Uses the calibrated seismic element and rigid stud mounting to maintain frequency response.
Technical Details
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Part Number | 9200-01-02-02-00 |
| Measurement Principle | Two-wire moving-coil velocity transducer |
| Orientation / Minimum Frequency | 01 — 0° ±2.5° / 4.5 Hz (270 cpm) |
| Connector | 02 — side mount, no cable |
| Mounting Base | 02 — circular, 1/4-28 UNF stud |
| Agency Approval | 00 — no approvals |
| Sensitivity / Temperature | 20 mV/mm/s / -29°C to +121°C |
System Integration
- Prepare a flat, rigid mounting surface and install the stud base at the calibrated angle.
- Allow side-connector clearance and route a shielded two-conductor cable away from power wiring.
- Connect to a monitor input configured for the Seismoprobe sensitivity and expected frequency band.
- Verify polarity, channel units and response with a controlled vibration or approved channel test.
Applications
- Bearing-housing and machine-casing vibration measurement
- Horizontal rotating-equipment installations requiring a low-frequency velocity signal
- Replacement of the same side-connector and stud-base execution
FAQ
Does 9200-01-02-02-00 require an external power supply?
No. It is a self-generating moving-coil transducer, but the monitor input and cable termination must still match the specified signal.
Can 9200-01-02-02-00 be installed at any angle?
No. The 01 execution is calibrated for its defined horizontal orientation range; a different mounting angle requires the appropriate order option.
Is a mating cable included with 9200-01-02-02-00?
No integral cable is specified. The side-mounted connector requires a compatible separate cable assembly.
Can 9200-01-02-02-00 replace 74712-06-03-04-00?
Not directly. Temperature range, orientation option, mounting base and connector execution differ and must all be reviewed.
What should be verified before commissioning 9200-01-02-02-00?
Confirm the rigid stud mount, angle, cable shield, input scaling, polarity and measured response across the machine operating range.
Recommended Models
| Balluff BNS 819-B02-R12-61-12-55-FD-1009 | 1SAP180100R0001 | E23 201122 |
| FS21002-11-07 | DDMC802-PB | KH57 AM145 |
| ST2620 SCR14ABAFNKG | 700-HLT12Z24 | BC-GT30 0103-003-00 |
| AC110/0013EB.4H50SGB-D | 1PH7137-2QF02-0CJ0 | BUSCH-JAEGER 6586/14 |
| PIB01CB23500MA | GWB 64 307138 | DIM-6CH-2A |
| Krones DSC1-100S065U-10-54-AO9-DPPK-AN-O+AS1 | RM65V-16IBS-I 1827030156 | FG1625TAS |
| FGL 30 R-PSM3 830-11003 | ST39175LC | ABB DO561 1TNE968902R2201 |
| BWU2307 16512 | RH400380 | 65350 |
| 140S-MC1-3-1K1-2K | EMC2 API4SG10 712G p/n 071-000-521 | S4-34492 |
| SPS 201 A | E84DSMBC3024R2SLCE | Festo DSBC-32-70-PPVA-N3 |