Bently Nevada 991-06-70-03-05 Metric Thrust Transmitter
A metric-range 7 m thrust transmitter supplied for DIN or bulkhead mounting with the broad approval option.
Product Profile
991-06-70-03-05 is configured for a 0.6-0-0.6 mm axial-position range and a 7 m 3300 NSv transducer system. Mounting option 03 supplies both 35 mm DIN-rail clips and bulkhead screws.
Approval option 05 covers the documented CSA Division 2, ATEX Zone 0, ATEX Zone 2 and ABS maritime selections for this transmitter execution.
Technical Data
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Complete Model | 991-06-70-03-05 |
| Product Family | 991 Thrust Transmitter |
| Measurement Range | 0.6-0-0.6 mm |
| System Length | 7.0 m |
| Mounting Hardware | DIN-rail clips and bulkhead screws |
| Approval Selection | CSA, ATEX and ABS maritime options |
| Signal Output | 4–20 mA axial position |
| Diagnostic Access | PROX OUT and COM connection |
| Humidity Protection | Potted for condensing environments |
System Role
- Converts the matched NSv proximity signal into a control-system current loop.
- Provides local zero, span and diagnostic access during commissioning.
- Signals transducer-chain faults through low-current Not OK behavior.
Compatibility
- Use a 3300 NSv probe and extension cable totaling 7 m.
- Keep the metric span aligned with control-system scaling and alarm setpoints.
- Select DIN or bulkhead mounting without altering wiring clearances.
- Verify the applicable approval certificate and installation requirements for the destination site.
Applications
- Metric axial-position monitoring on compressors, pumps, motors and fans.
- Marine or hazardous-area packages requiring the exact approval execution.
- OEM machinery using a loop-powered transmitter instead of rack-based conditioning.
FAQ
Which approval documents should be requested with 991-06-70-03-05?
Request the documents applicable to the actual destination, including the relevant CSA, ATEX or ABS marking and installation conditions.
Can 991-06-70-03-05 replace a 25 mil range transmitter?
Do not assume so. Confirm engineering-unit scaling, alarm thresholds, calibration span and controller logic before any range change.
Does 991-06-70-03-05 support both mounting methods?
Yes, option 03 supplies DIN-rail clips and bulkhead screws, but the enclosure and wiring layout still require verification.
What is required to preserve the 7 m system for 991-06-70-03-05?
The NSv probe length plus extension-cable length must equal the Proximitor system length selected by the transmitter.
What should a receiving inspection for 991-06-70-03-05 include?
Check the complete suffix, approval markings, terminals, mounting hardware, calibration controls and physical condition before installation.
What field tests should close a 991-06-70-03-05 replacement?
Document gap, diagnostic voltage, zero and span, 4–20 mA scaling, Not OK current and every alarm or shutdown action.
Recommended Models
| ARS 315 D C32 B0020038 | H10-106QW | IF772 |
| TONNA | QUINT-PS/1AC | Converteam ALSPA MD2000 144-400 |
| MQDEC-830-12M23RA | STTB 2.5/2P-PV | X20SO4110 |
| PGB 470A | DIL 3 H | MM311U |
| Indramat MAC112C-0-HD-4-C/180-A-2/WI520LV/S029 | EM31 | WMS-117-319 |
| 6AV7875-0BE20-0AB0 | KBS 71L4 | LS610-DA-IBS/F2 |
| UK5-MTK 3004430 | UTD 6/SP 3072817 | 630 6032_G.2D |
| RA 0010 B 501 | ACC-EDK-3A | CIFX50-RE |
| CCH-CS | HA4802XC | IS36/13560, 971110 |
| TXM1.8X | YN44PA3 | 80PS080X3.10-01 |