Bosch Rexroth HMD01.1N-W0012-A-07-NNNN Double-Axis Inverter
The complete IndraDrive M designation for the submitted HMD01.1N-W0012 double-axis inverter reference.
Product Identification
HMD01.1N-W0012-A-07-NNNN is a compact double-axis inverter in the modular IndraDrive M system. The official complete type code resolves the abbreviated submitted reference and should be used for identity control.
The inverter operates from the IndraDrive DC bus and must be coordinated with the supply unit, control sections, motors, feedback systems and cabinet cooling design.
Engineering Data
| Manufacturer | Bosch Rexroth |
|---|---|
| Complete Type Code | HMD01.1N-W0012-A-07-NNNN |
| Submitted Reference | HMD01.1N-W0012 |
| Material Number | R911306439 |
| Product Family | IndraDrive M |
| Axis Configuration | Double-axis inverter |
| Maximum Current | 12 A |
| Rated Current | 6.9 A |
| Typical Motor Rating | 3 kW |
| DC Bus | 254–750 V DC |
| Cooling | Fan-cooled |
| Protection Class | IP20 |
Functions
- Controls two motor axes from one compact modular inverter housing.
- Shares the IndraDrive DC-bus architecture with the matching supply and adjacent drive modules.
- Uses replaceable control sections selected for the required feedback, communication and safety functions.
- Reduces cabinet width while retaining separate axis commissioning and diagnostics.
Applications
- Compact multi-axis machine modules
- Packaging and handling systems
- Coordinated servo axes in IndraDrive M cabinets
Lifecycle
- Keep the complete type and material numbers with the machine bill of materials.
- Archive parameter sets for both axes and the fitted control sections.
- Include fan condition and DC-bus connections in preventive maintenance.
FAQ
Why is HMD01.1N-W0012-A-07-NNNN longer than the submitted reference?
The submitted string was abbreviated; the complete official type code is required to identify the exact IndraDrive M execution.
Can HMD01.1N-W0012-A-07-NNNN run as a stand-alone mains drive?
It is a modular inverter supplied from the IndraDrive DC bus, so the matching supply and cabinet architecture are required.
What must be checked for both axes of HMD01.1N-W0012-A-07-NNNN?
Confirm both motors, feedback devices, brakes, control sections, parameters, current demand and safety assignments.
Can one failed axis justify replacing HMD01.1N-W0012-A-07-NNNN?
Diagnosis should first separate the inverter, motor, feedback, cable and control-section causes because the housing serves two axes.
What should accompany an HMD01.1N-W0012-A-07-NNNN enquiry?
Provide complete labels, material number, control-section types, supply-unit model, motor labels, firmware context and both parameter backups.
Which commissioning checks follow HMD01.1N-W0012-A-07-NNNN replacement?
Verify axis mapping, feedback polarity, brakes, safety functions, limits, tuning and coordinated operation under controlled conditions.