Bosch Rexroth HMS01.1N-W0036-A-07-NNNN Single-Axis Inverter
The complete official designation for the submitted HMS01.1N-W0036-A-07-NN IndraDrive M reference.
Product Identification
HMS01.1N-W0036-A-07-NNNN is a single-axis inverter in the modular IndraDrive M family. The completed suffix provides the catalog identity needed for material and configuration checks.
The module works within an IndraDrive DC-bus system and receives its axis-specific behavior from the fitted control section, firmware and parameter set.
Engineering Data
| Manufacturer | Bosch Rexroth |
|---|---|
| Complete Type Code | HMS01.1N-W0036-A-07-NNNN |
| Submitted Reference | HMS01.1N-W0036-A-07-NN |
| Material Number | R911295324 |
| Product Family | IndraDrive M |
| Axis Configuration | Single-axis inverter |
| Maximum Current Class | 36 A |
| Cooling | Fan-cooled |
| Protection Class | IP20 |
| Supply Architecture | IndraDrive modular DC bus |
Functions
- Controls one servo axis within the modular IndraDrive M cabinet architecture.
- Accepts the application-specific control section used for feedback, fieldbus and safety integration.
- Shares the DC bus with the coordinated IndraDrive supply and adjacent inverter modules.
- Provides a narrow 50 mm module format for dense multi-axis cabinets.
Applications
- Single machine axes in modular drive systems
- Packaging, printing and handling equipment
- Replacement in documented IndraDrive M cabinets
Lifecycle
- Record the material number and control-section identity with the drive asset.
- Maintain parameter and firmware backups after approved changes.
- Inspect fan, DC-bus and power connections during preventive service.
FAQ
Why is HMS01.1N-W0036-A-07-NNNN used instead of the submitted short string?
The submitted suffix was incomplete; the official complete type code is needed for exact catalog identification.
Can HMS01.1N-W0036-A-07-NNNN connect directly to mains power?
It is a modular IndraDrive M inverter and depends on the matching DC-bus supply architecture.
Does HMS01.1N-W0036-A-07-NNNN include the control-section configuration?
The inverter identity alone does not define every control, feedback, communication and safety feature; verify the fitted control section.
What should accompany an HMS01.1N-W0036-A-07-NNNN enquiry?
Provide inverter and control-section labels, material number, supply-unit model, motor plate, firmware context and parameter backup.
Can a different current-class HMS module replace HMS01.1N-W0036-A-07-NNNN?
Not automatically. Motor current, protection, DC-bus design, control section, dimensions, cooling and commissioning must be reviewed.
What tests follow HMS01.1N-W0036-A-07-NNNN replacement?
Verify DC-bus readiness, feedback, motor direction, brake, safety functions, limits, communication and controlled-load behavior.