  • Product NameEaton Crouse-Hinds MTL5544D HART Repeater Power Supply with Dual Outputs
  • Item NO.3742403
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • Brandothers
  • Creation Time2026-08-20
Eaton Crouse-Hinds MTL5544D HART Repeater Power Supply with Dual Outputs | HTML Preview

Eaton Crouse-Hinds MTL5544D HART Repeater Power Supply with Dual Outputs

ManufacturerEatonModelMTL5544DProduct TypeHART Repeater Power Supply, Dual Output

01Technical Summary

The Eaton Crouse-Hinds series MTL5544D is a DIN-rail-mounted, one-channel repeater power supply for a two- or three-wire 4...20 mA transmitter in a hazardous area. It repeats one field-loop current into two isolated safe-area loads and supports bidirectional HART communication through channel 1 for compatible two-wire transmitters.

Selection ControlMatch the exact model, part number, installed system, wiring, approvals, and required revision before ordering.

02Applications

  • Dual indication or control paths from one hazardous-area 4...20 mA transmitter.
  • Safety and control architectures that require two isolated safe-area current outputs.
  • HART maintenance access through the channel 1 output path.
  • DIN-rail-mounted MTL5500 intrinsic-safety interface systems.

03Specifications

Manufacturer Eaton
Model MTL5544D
Product Type Repeater power supply with dual outputs
Number of Field Channels 1
Safe-Area Outputs 2
Transmitter Types 2-wire or 3-wire 4...20 mA
Supply Voltage 20...35 V DC
Input Range 0...24 mA including overrange
Output Signal Range 4...20 mA
Output Overrange 0...24 mA
Load at 20 mA 0...450 ohm per output
Load at 24 mA 0...360 ohm per output
Transmitter Voltage 16.5 V at 20 mA
Transfer Accuracy at 20 deg C Better than 15 uA
Temperature Drift <0.8 uA per deg C
Response Time Within 10% of final value in 50 us
HART Support Channel 1 only
Maximum Current Consumption 96 mA at 24 V DC with 20 mA signals
Power Dissipation 1.4 W at 24 V DC with 20 mA signals
Functional Safety SIL3 capable under documented IEC 61508 use conditions

04Features

Design and Function

  • Powers one hazardous-area transmitter and drives two safe-area current loads.
  • Fully floating field supply and isolated safe-area output circuits.
  • Bidirectional HART communication is supported through channel 1 for two-wire transmitters.
  • Separately powered four-wire current sources may be connected, but HART is not supported for that arrangement.
  • Green LED indicates power.
  • No operator configuration switches are required for the module function.
  • Functional-safety documentation covers use in safety instrumented functions.

Verified Identity

  • Manufacturer: Eaton Model: MTL5544D Product Type: HART Repeater Power Supply, Dual Output

05Compatibility

  • A suitable load must be present on both outputs for correct operation.
  • HART communication is available on channel 1 only.
  • Confirm two-wire or three-wire transmitter wiring and the 20...35 V DC supply.
  • Verify entity parameters, hazardous-area classification, and loop certification before installation.
  • MTL4544D is functionally related but uses MTL4500 backplane mounting; it is not a DIN-rail drop-in replacement.

06Maintenance & Replacement

  • Record both safe-area load circuits and the HART connection path before removal.
  • Do not leave either output unloaded during commissioning tests if transfer accuracy is being evaluated.
  • After replacement, verify current transfer to both loads across the operating range.
  • Test HART communication through channel 1 and confirm no HART requirement exists on channel 2.
  • Follow the current Eaton safety manual when the module is part of a SIL application.

FAQFrequently Asked Questions

How many field channels does MTL5544D have?

It has one hazardous-area transmitter channel.

How many safe-area outputs are provided?

It repeats the field current into two safe-area outputs.

Which output supports HART?

Bidirectional HART communication is supported through channel 1 only.

Can a four-wire transmitter be connected?

A separately powered current source can be connected, but HART communication is not supported in that arrangement.

What supply voltage is required?

The documented supply range is 20...35 V DC.

Is the module SIL capable?

Yes. Eaton documents SIL3 capability subject to the applicable safety manual and system architecture.