DC/DC POWER CONVERSION · MULTI-RAIL OUTPUT · COMPONENT SUPPLY

Emerson 73-610-096 DeltaV S-Series DC/DC Component Power Supply

A DeltaV S-Series component power supply with selectable 24 V or 12 V input ratings and regulated 12 V, 5.1 V and 3.4 V outputs.

24 V input mode6.1 A, ±20%
12 V input mode14.8 A, −4% / +5%
Temperature range−40 to +70 °C, derated at upper limit
01
ASSET RECORD

Product Identification

73-610-096 is an Emerson DeltaV S-Series DC/DC component power supply. Certified ratings cover 24 V DC and 12 V DC input modes, with separate 12 V, 5.1 V and 3.4 V output rails.

It is a component supply intended for incorporation into approved equipment. The complete label, input mode, host assembly, airflow and alarm-contact wiring must therefore be checked as part of the system rather than treating the power supply as a stand-alone field device.

The complete 73-610-096 label controls the certified input and output profile and the host-equipment integration record.
02
CONFIGURATION REGISTRY

Engineering Data

Product type
DC/DC component power supply
24 V input rating
6.1 A at 24 V DC, ±20%
12 V input rating
14.8 A at 12 V DC, −4% / +5%
12 V output on 24 V input
8 A
12 V output on 12 V input
13 A
Auxiliary outputs
5.1 V at 2 A; 3.4 V at 2 A
Combined auxiliary output limit
10.2 W maximum for 5.1 V and 3.4 V rails
Alarm contacts
30 V DC, 2 A
Operating range
−40 to +70 °C, with output derating at 70 °C
Installation classification
Component power supply for incorporation into approved equipment
03
OPERATING ROLE

Functions

01

Convert cabinet DC power

Produces the required 12 V, 5.1 V and 3.4 V rails from the approved DC input.

02

Expose supply status

Alarm contacts provide a defined interface for host-equipment supervision.

03

Support extended environment

The certified component range covers low-temperature startup and high-temperature derated service.

04
FIELD PLACEMENT

Applications

DeltaV S-Series cabinet power

Use within the identified host assembly and approved environmental design.

Controlled power-supply exchange

Match input mode, rail loading and connector record before removing the installed unit.

Approved enclosure integration

Maintain the host enclosure, protection and cooling conditions required by the certification.

05
MAINTENANCE CONTROL

Lifecycle

01

Record

Capture 73-610-096, host assembly, input mode, output loads, connectors and alarm wiring.

02

Assess

Calculate rail loading and confirm airflow, ambient temperature and enclosure protection.

03

Exchange

Isolate all input sources and follow the approved cabinet energy-control procedure.

04

Verify

Measure output rails, confirm alarm operation and monitor the host system under normal load.

IndustryParts industrial parts support
INDUSTRIAL SPARE-PART SUPPORT

About IndustryParts

https://www.industryparts.com/

Controlled handling for 73-610-096

IndustryParts keeps the submitted 73-610-096 identity, requested quantity and installed-system evidence together so a proposed supply can be checked before dispatch.

  • Suffix and MOD identity kept visible
  • Mating hardware recorded before supply
  • Acceptance evidence linked to the order
07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

Can 73-610-096 be treated as a stand-alone power supply?

No. Its certifications identify it as a component power supply whose suitability is determined in the host equipment.

Q02

What input record is needed for 73-610-096?

Provide the selected 24 V or 12 V mode, source tolerance, protection and measured cabinet load.

Q03

Why must all output rails be documented for 73-610-096?

The 12 V rating changes with input mode and the 5.1 V plus 3.4 V outputs share a 10.2 W combined limit.

Q04

What should accompany a 73-610-096 request?

Send the complete label, host cabinet identity, connector photographs, rail loads and alarm-contact arrangement.

Q05

What proves 73-610-096 is ready after exchange?

Document stable 12 V, 5.1 V and 3.4 V rails, normal alarm state and correct host operation under load.