Home>DCS>Emerson EPRO PR6423/03R-012-ZD Eddy-Current Displacement Sensor

Hot Categories

Emerson EPRO PR6423/03R-012-ZD Eddy-Current Displacement Sensor

Emerson EPRO PR6423/03R-012-ZD Eddy-Current Displacement Sensor

Item NO.: 3787305

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson EPRO PR6423/03R-012-ZD Eddy-Current Displacement Sensor
  • Item NO.3787305
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEpro
  • Creation Time2026-10-09
EMERSON EPRO | PR6423 | NON-CONTACT SHAFT MEASUREMENT

Emerson EPRO PR6423/03R-012-ZD Eddy-Current Displacement Sensor

An exact-suffix PR6423 eddy-current probe for non-contact shaft position and vibration measurement, requiring suffix and converter matching.

BrandEmerson
ModelPR6423/03R-012-ZD
Product TypeEPRO Eddy-Current Displacement Sensor
01

Technical Summary

PR6423/03R-012-ZD is an Emerson EPRO PR6423 eddy-current displacement sensor configuration. The PR6423 family measures static and dynamic shaft displacement without contact and is used for radial vibration, axial position, eccentricity, differential expansion, valve position and air-gap measurement.

PR6423 systems use a compatible CON converter and a matched cable path. The /03R-012-ZD suffix must remain intact because it defines the mechanical and connection configuration; those details should be verified from the exact sensor label and project documentation.

02

Specifications

Manufacturer Emerson
Model PR6423/03R-012-ZD
Sensor Principle Non-contact eddy-current displacement measurement
Measured Variables Static and dynamic shaft displacement
Typical Uses Radial vibration; axial position; eccentricity; differential expansion; valve position; air gaps
Applicable Standards DIN 45670, ISO 10817-1 and API 670
Compatible Converter Families CON 011/91, CON 021/91 and CON 041/91
Target Basis Electrically conductive steel shaft
System Matching Probe, cable and converter are treated as one calibrated chain
Suffix Control Verify /03R-012-ZD mechanical, cable and termination details from the exact label
03

Features

  • Measures shaft motion and position directly through the bearing arrangement.
  • Supports both protection and condition-monitoring applications on sleeve-bearing machinery.
  • Works with dedicated CON signal converters as a complete transducer system.
  • Retains the exact suffix needed for probe geometry, cable and connection control.
04

Compatibility

  • Match the complete PR6423/03R-012-ZD label, mounting geometry and cable system.
  • Confirm CON converter type, calibrated system length, target material and monitor input.
  • Verify probe gap, bracket stiffness, thread or holder, cable routing and connector form.
  • Do not interchange PR6423 suffixes solely because the sensing tip looks similar.
05

Replacement

  • Record probe label, converter label, cable sections, total system length and installed gap voltage.
  • Protect the tip and cable from impact, tight bends and connector contamination.
  • After installation, set mechanical gap, verify linear response and polarity, and establish a new vibration baseline.
06

FAQ

PR6423/03R-012-ZD: What must be quoted as one measurement chain?

Identify the probe, extension or integral cable, CON converter, total system length, monitor channel and target material.

PR6423/03R-012-ZD: Can an existing CON converter be retained?

Only after confirming the converter family, calibration, cable length and probe configuration are compatible with the replacement.

PR6423/03R-012-ZD: Which field measurements help validate a replacement?

Record cold gap voltage, mechanical gap, slow-roll runout, polarity, monitor scaling and a stable-speed vibration baseline.

PR6423/03R-012-ZD: What information is needed when the probe suffix is partly unreadable?

Provide photographs, thread or holder dimensions, sleeve length, cable construction, connector, converter label and project drawings.

PR6423/03R-012-ZD: How can cable-related false vibration be reduced?

Secure the cable, maintain bend radius, protect connectors, separate it from noise sources and avoid movement at the probe exit.

PR6423/03R-012-ZD: What acceptance documentation should accompany a calibrated system?

Request traceable identities for probe and converter, system-length confirmation, linearity or calibration results and condition statement.

You May Also Like