Provides non-contact shaft displacement or vibration measurement in a reverse-mount installation.
Product Overview
EZ1080-RM-00-005 is an Emerson AMS EZ 1000 eddy-current sensor. The RM code identifies the reverse-mount execution with an integrated lock nut.
The exact order code specifies an 8 mm tip, M10x1 case thread, no unthreaded length and a 0.5 m integral cable.
The EZ108x family has a standard 2 mm (80 mil) measuring range, oil-proof construction and a Lemo connection for the compatible cable and EZ1000 converter chain.
Performance
Fits the compatible AMS EZ 1000 probe-holder arrangement documented for EZ108x reverse-mount sensors.
Works as part of a calibrated sensor, cable and EZ1000 converter chain.
Uses the short 0.5 m cable code so total system length must be completed with the correct extension cable.
Technical Details
| Manufacturer | Emerson AMS |
|---|---|
| Exact model | EZ1080-RM-00-005 |
| System family | AMS EZ 1000 |
| Sensor type | Eddy-current proximity sensor |
| Mounting execution | Reverse mount with integrated lock nut |
| Tip diameter | 8 mm |
| Standard measuring range | 2 mm (80 mil) |
| Case thread | M10x1 |
| Unthreaded length | 0 mm |
| Integral cable length | 0.5 m |
| Cable armor | None |
| Connector | Lemo |
| Sensor construction | Oil-proof |
| Compatible holder context | AMS EZ 1000 holder configurations for EZ108x reverse-mount sensors |
System Integration
- Use only with the compatible EZ1000 converter configuration and approved system-cable length.
- Select the required EZ190x extension cable for the 0.5 m sensor cable where the system chain requires it.
- Confirm the reverse-mount holder, lock-nut access and insertion range.
- Calibrate for the actual target material and complete chain after installation.
Applications
- Reverse-mounted probe-holder installations on rotating machinery.
- Shaft relative-vibration and position measurement with controlled probe access.
- Turnaround replacement where short sensor cable plus extension cable supports maintainability.
- AMS EZ 1000 inventory strategies using field-configurable converters.
About IndustryParts
https://www.industryparts.com/Reverse mount and cable length are separate selection points
IndustryParts keeps EZ1080-RM-00-005 tied to its holder, integrated lock nut, short cable and calibrated EZ 1000 measurement chain.
- Reverse-mount execution verified
- 0.5 m cable retained
- Holder and calibration records requested
FAQ
How is EZ1080-RM-00-005 different from EZ1080-10-00-010?
EZ1080-RM-00-005 is reverse mount with an integrated lock nut and 0.5 m cable; EZ1080-10-00-010 has a 100 mm standard case and 1.0 m cable.
What should accompany an EZ1080-RM-00-005 enquiry?
Send the complete sensor, holder, extension-cable and converter codes, target material, required total length, insertion range and quantity.
Does the 0.5 m cable complete the EZ1080-RM-00-005 system length by itself?
Usually the documented short sensor-cable options use a compatible extension cable. Confirm the total system length and converter setting for the installed chain.
What mechanical evidence matters before replacement?
Record holder model, insertion depth, lock-nut position, probe gap, cable route and available withdrawal clearance before removal.
What proves EZ1080-RM-00-005 is ready for service?
Confirm the exact reverse-mount code, secure holder and lock nut, correct total cable length, complete-chain calibration, stable gap voltage and approved alarm-path test.
Recommended Models
| TPCX57203 | PQ502 502-34E1 G19200D000 | SEW, K97 R57 DRN100L4/TF |
| AZ5110 | OJ5054 OJHLFPKG/SA/AS | 75000 E6173A |
| H7080B2103 | FS 4865-8-29 3EF-08 | CF10-50N |
| X20CP3584 | 6ES5 470-8MC11 | 5GN3.6RAA |
| 6FX1111-0AN02 | TLS2-GD2 | Sick WS27-3D2430 |
| GCD-0001 8XP-W | 4PP035 | DL-230CPU D2-16ND3-2 D2-08CDR D2-12TR |
| X20DO8331 | MCR-SL-S-1/5-I-DCI-24 | PB42 |
| FXPM24 | FX-PCX4711-0 | 3RM1207-1AA04 |
| AKM115SF132 | ALM-1 | 1LE1003-1EB43-3AB4 |
| 6EP1931-2EC21 | Prok Dv'S El01 | 23614-K/20070219 |