Universal slot field
Provides twelve positions for compatible RX3i and supported legacy-format modules under system rules.
Warranty: 1 year
Condition : brand new in factory sealed box
Email: sales@mvme.cn
Chat online: +86 18030175807
A twelve-slot PACSystems RX3i universal backplane used to carry compatible CPU, communication and I/O modules.
IC695CHS012 is the twelve-universal-slot RX3i base catalog documented by Emerson. It establishes the physical module positions and the backplane communication and power path for the installed rack.
This page covers the unsuffixed IC695CHS012 identity only. Revision-suffixed bases remain separate records because later CPUs can require minimum backplane hardware or firmware levels.
Emerson / GE Fanuc
IC695CHS012
PACSystems RX3i
Universal backplane
12
IC695CHS012
Read from the installed label
CPU manual and backplane revision
Installed supply and total rack load
Rack position and module-slot map
Provides twelve positions for compatible RX3i and supported legacy-format modules under system rules.
Distributes the installed power and backplane communication path across the configured module set.
Keeps the physical position of each CPU, communication and I/O module available for service records.
Requires the backplane label to be checked against minimum revision and firmware requirements of later controllers.
Building a twelve-position PACSystems base around an approved supply and CPU.
Retaining compatible module positions while moving an application into the RX3i platform.
Replacing a damaged base only after slot, load and revision records are captured.
Photograph every slot and record each catalog number, blank position, supply and CPU.
Review rack current, module compatibility and the backplane revision required by the controller.
Reinstall by the approved slot map, restore the project and verify all module and bus diagnostics.
Provide clear backplane-label photographs, the complete slot map, power-supply catalog number, CPU identity and quantity.
No. The suffix is part of the hardware identity and should not be removed or transferred between records.
Some later controllers require a minimum backplane revision or firmware level, so the CPU and base must be reviewed together.
Use the current requirement of every installed module and the selected power supply instead of assuming the previous base defines capacity.
Confirm the slot map, module recognition, rack power margin, clean diagnostics and successful application I/O tests.
IndustryParts prepares IC695CHS012 enquiries around the complete manufacturer label, requested quantity and installed-system evidence. Share the application record that distinguishes this execution before a supply proposal is prepared.
Send the complete IC695CHS012 label, requested quantity and delivery destination.