Emerson IC200BEM003-CA VersaMax PROFIBUS DP Master
A VersaMax communication module that gives a supported controller or PROFINET station PROFIBUS DP master capability.
Overview
IC200BEM003-CA is the CA hardware revision of the IC200BEM003 VersaMax PROFIBUS DP Master module. It adds a PROFIBUS master function within the compact VersaMax modular I/O architecture.
The complete revision suffix matters because firmware and host compatibility can change across hardware releases. Preserve the configuration, slave definitions and physical-network records before replacing an installed module.
Specs
| Manufacturer | Emerson / GE Intelligent Platforms |
|---|---|
| Model | IC200BEM003-CA |
| Base Catalog Number | IC200BEM003 |
| Hardware Revision | CA |
| Product Family | VersaMax modular control and I/O |
| Module Function | PROFIBUS DP Master |
| Module Manual | GFK-2740 |
| Supported Integration | Manufacturer documentation lists support within VersaMax PROFINET Scanner systems from the applicable scanner firmware releases |
| Configuration Asset | PROFIBUS project and device description files must match the installed slaves |
Features
- Provides PROFIBUS DP master communications in a VersaMax modular station.
- Keeps the network role within the same compact carrier-based I/O family.
- Uses controller engineering software to define slaves, data sizes and diagnostic behavior.
- Retains the CA revision so a quotation does not collapse distinct hardware releases into one generic module.
Applications
- Legacy PROFIBUS remote-I/O and machine-control stations.
- Replacement of an installed IC200BEM003-CA while preserving slave addresses and data mapping.
- Migration projects that must reproduce an existing VersaMax PROFIBUS segment before controller modernization.
Lifecycle
- Export the hardware configuration and PROFIBUS network project before removal.
- Record module revision, host scanner/controller firmware and every slave GSD version.
- Inspect connectors, shielding, termination and station addressing before changing hardware.
- After replacement, compare live slave diagnostics and I/O mapping before releasing automatic control.
FAQ
Which records are needed to quote an exact IC200BEM003-CA replacement?
Send the complete label, CA revision, host controller or scanner model, firmware levels, PROFIBUS project and a slave inventory.
Can a different IC200BEM003 revision replace IC200BEM003-CA without review?
Do not assume so. Confirm hardware and firmware compatibility with the host station and engineering software before changing the suffix.
What usually causes a replacement IC200BEM003-CA to show missing slaves?
Mismatched addresses, GSD revisions, bus termination, cable/shield faults or an incomplete configuration download should be checked before condemning the module.
Which commissioning check for IC200BEM003-CA is more useful than repeating its specifications?
Compare the configured and live slave list, input/output data lengths and diagnostic states against a known-good project backup.
What migration risk should be assessed around IC200BEM003-CA?
A newer controller or PROFINET gateway can change byte ordering, diagnostic handling and update timing, so the PLC and HMI mappings require a controlled validation.
Recommended Models
| X20AIB744 | MILLENIUM3 CD12 | BMXNOM0200 |
| TWK-S 07 555 | Grimm Feed Technology RF40-2 R + FAR-1 | SF57 DRE90M2BE1/Z/LN |
| 1LA9183-4WA60-Z | 909.0262.900 | Compact NS160 H TM 160 D |
| 31F761.9 | ABB 1SVR730020R0200 | DCRE12 |
| 51453540.001 | 692.916107141 | D1092S |
| FTS07-0161-2 | SM 91.10 | ZRVL-150 |
| FC-2000 | BLR-CX 12RL | MDV64ME08DX13HER242122122FE00XXXX00 |
| SEW KT67/T DRP100L4/MM22/AMA6/EI71 | X67AI1223 | C-9402 |
| T5B-4-8902/E | Interroll 138i 1194303 | 3AO350.6 |
| Lenze 33.8610_E 00356139 | 8650200.6220.12000 | MB-402 |