Home>DCS>Emerson IC200CPUE05-CG CPUE05 Controller with Ethernet, Revision CG

Hot Categories

Emerson IC200CPUE05-CG CPUE05 Controller with Ethernet, Revision CG

Emerson IC200CPUE05-CG CPUE05 Controller with Ethernet, Revision CG

Item NO.: 3810468

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC200CPUE05-CG CPUE05 Controller with Ethernet, Revision CG
  • Item NO.3810468
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-27
VersaMax PLCTECHNICAL PRODUCT RECORD
VERSAMAX CPU · ETHERNET · 64 KB CONFIGURABLE MEMORY

Emerson IC200CPUE05-CG CPUE05 Controller with Ethernet, Revision CG

A VersaMax controller with serial communications and an embedded 10 Mbps Ethernet interface.

Memory64 KB maximum
Ethernet10 Mbps, RJ45
RevisionCG retained
01
PRODUCT DOSSIER

Key Information

IC200CPUE05-CG is the CG-revision identity of Emerson IC200CPUE05. The controller combines VersaMax application execution with RS-232, RS-485 and a 10 Mbps half/full-duplex Ethernet interface.

Emerson lists battery-backed RAM and system flash program storage, a 64 KB maximum configurable memory allocation and floating-point support. The Ethernet interface supports eight SRTP server connections plus configured EGD exchanges.

The CG suffix is preserved as the exact installed release. Firmware, memory allocation and protocol use must be confirmed from the controller and project rather than inferred from the suffix alone.

02
OPERATING ROLE

Functions

A

Control execution

Runs the VersaMax control program and updates local or networked I/O.

B

Embedded Ethernet

Provides an RJ45 10 Mbps path for supported SRTP, EGD, NTP and station-manager services.

C

Serial integration

Retains RS-232 and RS-485 communications for configured devices and maintenance paths.

D

Program retention

Uses battery-backed RAM and system flash to maintain the approved application record.

03
MANUFACTURER DATA

Specifications

Manufacturer
Emerson
Exact model
IC200CPUE05-CG
Controller
VersaMax CPUE05
Installed revision
CG
Maximum configurable memory
64 KB
Program storage
System flash and battery-backed RAM
Ethernet
10 Mbps, half/full duplex, RJ45
SRTP server connections
8
EGD configuration exchanges
32
Data ranges per exchange
100
Maximum data per exchange
1400 bytes
Serial interfaces
RS-232 and RS-485
Boolean execution
0.8 ms/K typical
IndustryParts industrial automation supply support
DOCUMENTED INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

Exact-model handling for IC200CPUE05-CG

IndustryParts keeps the complete model label, requested quantity, application evidence and delivery requirements together so the proposed supply can be checked against the installed system before dispatch.

04
CONTROLLED WORK

Installation

Freeze the controller baseline

Save program, memory allocation, firmware, port settings, IP configuration, EGD exchanges and fault tables.

Match revision and interfaces

Compare the CG label, rack power, serial wiring, Ethernet topology and software support before exchange.

Recover under supervision

Restore the approved application, validate I/O and communications, then complete a controlled restart and retention test.

05
SERVICE RECORD

Lifecycle

Backup custody

Keep a readable project and firmware record independent of the installed CPU.

Network governance

Document enabled services, addresses and EGD relationships before any maintenance window.

Battery and clock review

Include memory retention and real-time-clock behavior in planned service checks.

07
CUSTOMER QUESTIONS

FAQ

Q01

Which files should accompany a IC200CPUE05-CG enquiry?

Provide the project archive, firmware version, memory allocation, network export, serial-port settings, rack list and complete CPU label.

Q02

How many SRTP server connections does IC200CPUE05-CG support?

Emerson publishes eight server connections for the embedded Ethernet interface.

Q03

What must be reviewed before another CPUE05 suffix replaces IC200CPUE05-CG?

Compare hardware and firmware releases, memory retention, protocol behavior and software compatibility before approval.

Q04

Why should EGD configuration be captured for IC200CPUE05-CG?

The controller can hold 32 configured exchanges with multiple ranges; those relationships affect network recovery after replacement.

Q05

How is IC200CPUE05-CG accepted after service?

Verify program checksum, retained data, real-time clock, serial links, Ethernet exchanges, I/O response and supervised restart.

You May Also Like