Home>DCS>Emerson IC200CPUE05-MV VersaMax CPU with Ethernet Interfaces

Hot Categories

Emerson IC200CPUE05-MV VersaMax CPU with Ethernet Interfaces

Emerson IC200CPUE05-MV VersaMax CPU with Ethernet Interfaces

Item NO.: 3813291

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC200CPUE05-MV VersaMax CPU with Ethernet Interfaces
  • Item NO.3813291
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-29
ETHERNET CPU · RS-232 / RS-485 · MV EXECUTION

Emerson IC200CPUE05-MV VersaMax CPU with Ethernet Interfaces

A VersaMax controller with integrated Ethernet, serial communications, configurable memory and retained MV hardware identity.

ControllerVersaMax CPU
Ethernet10 Mb/s
Memory64 KB configurable
01
ASSET RECORD

Product Identification

IC200CPUE05-MV combines VersaMax controller execution with Ethernet, RS-232 and RS-485 communications. Program and data allocations share configurable memory, and the controller supports floating-point operations, a battery-backed real-time clock and network services for the installed automation node.

The MV suffix remains part of the service identity. A replacement decision should retain the full label, firmware and Machine Edition project as one record rather than relying on the base IC200CPUE05 family name.

Use the complete IC200CPUE05-MV label together with the project checksum, firmware release, Ethernet addressing and serial-port use; a base catalog match alone does not reproduce the installed controller state.
02
CONFIGURATION REGISTRY

Engineering Data

Controller platform
VersaMax
Maximum configurable memory
64 KB
Boolean execution
0.8 ms per K typical
Ethernet interface
10BASE-T, RJ45, half- or full-duplex
Ethernet server resources
Up to 8 SRTP server connections
EGD capacity
32 exchanges; up to 100 data ranges and 1400 bytes per exchange
Serial interfaces
RS-232 and RS-485
5 V current requirement
220 mA
3.3 V current requirement
570 mA
Dimensions
126 × 128 × 69.1 mm
Clock accuracy
100 ppm
Retentive storage
System flash and battery-backed RAM
03
OPERATING ROLE

Functions

01

Execute

Runs the stored control program with boolean and floating-point processing for the local VersaMax station.

02

Exchange

Supports SRTP and Ethernet Global Data while retaining serial paths for the documented installation.

03

Retain

Maintains the approved program and clock-dependent records through system flash and battery-backed memory.

04

Diagnose

Provides controller, Ethernet and station information through the project environment and Station Manager.

IndustryParts industrial parts support
INDUSTRIAL SPARE-PART SUPPORT

About IndustryParts

https://www.industryparts.com/

Controlled handling for IC200CPUE05-MV

IndustryParts keeps the submitted IC200CPUE05-MV identity, requested quantity and installed-system evidence together so a proposed supply can be checked before dispatch.

  • Suffix and MOD identity kept visible
  • Mating hardware recorded before supply
  • Acceptance evidence linked to the order
04
FIELD PLACEMENT

Applications

Ethernet-connected machine control

Controller nodes that exchange deterministic project data with supervisory or peer equipment over the installed 10 Mb/s network.

VersaMax station modernization

Service work where the complete rack layout, serial duties and MV hardware record must remain unchanged.

Distributed automation

Local control with retained program execution and documented EGD or SRTP communication relationships.

05
MAINTENANCE CONTROL

Lifecycle

01

Archive

Back up the complete Machine Edition project, logic, reference tables, Ethernet settings and serial configuration.

02

Identify

Photograph the MV label and record firmware, memory allocations, clock state and battery condition.

03

Restore

Install only after rack and power checks, then load the approved project without changing addresses or exchange definitions.

04

Accept

Prove local I/O, serial channels, SRTP connections, every active EGD exchange and retentive behavior.

07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

What network evidence is needed for a IC200CPUE05-MV quotation?

Include IP addressing, duplex setting, SRTP relationships, EGD exchange records and the complete MV controller label.

Q02

How much configurable memory does IC200CPUE05-MV provide?

The official Emerson product record lists 64 KB maximum configurable memory shared by program and data allocations.

Q03

Does IC200CPUE05-MV replace a controller with different Ethernet resources automatically?

No. Connection counts, EGD definitions, firmware, serial duties and rack support must be reviewed before substitution.

Q04

What should be saved before removing IC200CPUE05-MV?

Save the project, reference tables, Ethernet and serial settings, firmware record, clock-dependent data and any retentive-state procedure.

Q05

What closes a IC200CPUE05-MV replacement record?

A passed controller start, I/O proof, communications test, time check and verification that approved retained values behave as intended.