Home>PLC>Emerson IC200PBI001-MH VersaMax PROFIBUS-DP Network Interface Unit

Hot Categories

Emerson IC200PBI001-MH VersaMax PROFIBUS-DP Network Interface Unit

Emerson IC200PBI001-MH VersaMax PROFIBUS-DP Network Interface Unit

Item NO.: 3817010

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC200PBI001-MH VersaMax PROFIBUS-DP Network Interface Unit
  • Item NO.3817010
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandEmerson
  • Creation Time2026-11-02
PROFIBUS-DP REMOTE I/O · VERSAMAX STATION INTERFACE · MH EXECUTION

Emerson IC200PBI001-MH VersaMax PROFIBUS-DP Network Interface Unit

A VersaMax remote-I/O network interface unit for PROFIBUS-DP, with the complete MH hardware execution retained.

NetworkPROFIBUS-DP
System roleRemote I/O network interface unit
ExecutionMH
01
ASSET RECORD

Product Identification

IC200PBI001-MH is the MH hardware execution of the Emerson VersaMax IC200PBI001 PROFIBUS-DP network interface unit. It connects a VersaMax remote I/O station to a PROFIBUS-DP master.

The module is not the same as the IC200BEM002 CPU-system PROFIBUS slave module. Station address, baud-rate behavior, GSD/project identity, attached I/O layout and power budget must all stay with the NIU replacement record.

The MH suffix and the IC200PBI001 base number identify the remote-I/O NIU, not a CPU-system communication module.
02
CONFIGURATION REGISTRY

Engineering Data

Product family
VersaMax modular I/O
Base catalog number
IC200PBI001
Exact execution
MH
Network
PROFIBUS-DP
System role
Remote I/O network interface unit
Station hardware
VersaMax carriers and supported I/O modules
Engineering evidence
Master project, GSD identity and station address
Physical evidence
Bus connectors, termination and complete station layout
03
OPERATING ROLE

Functions

01

Connect remote I/O to PROFIBUS

Exchanges cyclic station data with the configured DP master.

02

Coordinate the VersaMax station

Provides the network-side interface for the attached carrier and I/O layout.

03

Expose station diagnostics

Returns network and module information for commissioning and fault isolation.

04
FIELD PLACEMENT

Applications

Distributed machine I/O

Use where a PROFIBUS-DP master controls a documented VersaMax remote station.

Legacy network maintenance

Preserve address, bus segment and master configuration during replacement.

Controlled station expansion

Check supported I/O, power budget and project data before altering the module chain.

05
MAINTENANCE CONTROL

Lifecycle

01

Map

Record IC200PBI001-MH, station address, master identity, bus connector and full I/O order.

02

Archive

Save the PROFIBUS master project, GSD/device record and station data lengths.

03

Exchange

Preserve termination, shield bonding, address settings and the VersaMax module sequence.

04

Commission

Verify bus status, station diagnostics and every configured input and output point.

IndustryParts industrial parts support
INDUSTRIAL SPARE-PART SUPPORT

About IndustryParts

https://www.industryparts.com/

Controlled handling for IC200PBI001-MH

IndustryParts keeps the submitted IC200PBI001-MH identity, requested quantity and installed-system evidence together so a proposed supply can be checked before dispatch.

  • Suffix and MOD identity kept visible
  • Mating hardware recorded before supply
  • Acceptance evidence linked to the order
07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

Is IC200PBI001-MH the same as IC200BEM002?

No. IC200PBI001 is the remote-I/O PROFIBUS-DP NIU; BEM002 is a CPU-system network communication module.

Q02

What should accompany a IC200PBI001-MH quotation?

Provide the MH label, station address, bus connector, master project and complete VersaMax I/O sequence.

Q03

Why is PROFIBUS termination important for IC200PBI001-MH?

The station must remain correctly positioned within a terminated and shielded bus segment.

Q04

Can the station layout be changed during a IC200PBI001-MH swap?

Avoid combining changes; first restore the documented module order and project configuration.

Q05

What closes a IC200PBI001-MH replacement record?

Confirm stable PROFIBUS communication, correct station diagnostics and verified operation of every configured I/O point.