Provides an Ethernet-to-serial communication path for supported VersaMax Micro controllers.
Key Information
IC200SET001-HE is a VersaMax Micro Ethernet-to-serial interface identified for the 14, 23 and 28-point controller range. It provides the network-to-serial interface function used by the documented controller installation.
The HE suffix must remain part of the procurement identity. Network settings, serial protocol, controller model and firmware should be archived before replacement.
Functions
Extends network access to installations built around the 14, 23 or 28-point VersaMax Micro range.
Keeps serial-device communication attached to one configured controller and network record.
Supports service replacement when addressing and protocol settings are preserved.
Specifications
| Manufacturer | Emerson / legacy GE Fanuc |
|---|---|
| Exact model | IC200SET001-HE |
| Product family | VersaMax Micro |
| Product type | Ethernet-to-serial interface |
| Supported controller range | VersaMax Micro 14, 23 and 28-point controllers |
| Configuration boundary | Controller, Ethernet network and serial-device settings |
| Hardware revision | HE |
| Selection basis | Complete label and supported controller record |
Installation
- Export or record Ethernet addressing, serial framing, protocol parameters and controller configuration before removal.
- Photograph power, network and serial connections and label the destination of every cable.
- Confirm the installed VersaMax Micro controller is within the supported 14, 23 or 28-point range.
- After replacement, test network reachability and an actual serial transaction rather than relying on link indicators alone.
Lifecycle
- Keep the HE suffix, controller model, firmware and configured addressing in the spare record.
- Retain a rollback copy of the network and serial configuration before any change.
- Document connected serial equipment and timeout behavior for future troubleshooting.
About IndustryParts
https://www.industryparts.com/Communication settings remain part of the spare identity
IndustryParts handles IC200SET001-HE with its controller model, network addressing and serial-device configuration recorded together.
- HE revision retained
- Settings archived
- End device identified
FAQ
Which settings should be supplied for an IC200SET001-HE enquiry?
Provide the controller model, firmware, IP configuration, serial protocol, baud rate, framing and connected-device identity.
Can IC200SET001-HE be installed on any VersaMax controller?
The documented interface is for VersaMax Micro 14, 23 and 28-point controllers; verify the exact controller before selection.
Does replacing IC200SET001-HE require controller program changes?
Not necessarily, but communication parameters and any program references to the serial device must be checked against the archived configuration.
How should a communication fault be separated from an IC200SET001-HE fault?
Check power, Ethernet link, IP conflicts, serial wiring, framing and the remote device with known-good tests before replacing the interface.
What is the final acceptance test for IC200SET001-HE?
Prove network access, serial communication and the real controller-to-device data exchange under normal timeout and recovery conditions.