Home>DCS>Emerson IC694ALG221A PACSystems RX3i Four-Point Analog Current Input Module

Hot Categories

Emerson IC694ALG221A PACSystems RX3i Four-Point Analog Current Input Module

Emerson IC694ALG221A PACSystems RX3i Four-Point Analog Current Input Module

Item NO.: 3813289

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC694ALG221A PACSystems RX3i Four-Point Analog Current Input Module
  • Item NO.3813289
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-29
FOUR CURRENT INPUTS · ALG IN 4 · A REVISION

Emerson IC694ALG221A PACSystems RX3i Four-Point Analog Current Input Module

A four-point analog current input module whose A revision and current-input identity must remain distinct from the voltage-input companion model.

01

Technical Summary

PRODUCT CONTEXT

IC694ALG221A is a four-channel analog current input module used in compatible PACSystems RX3i and legacy Series 90-30 arrangements. It digitizes field-current signals for the controller while keeping the four input points under one catalog identity.

The final A suffix is part of the submitted hardware record. It should not be dropped during quotation, and the module should not be confused with IC694ALG220A, which is the four-point voltage-input variant.

02

Specifications

CONTROLLED DATA
Input type

Analog current

Input points

4

Controller class

ALG IN 4

Hardware revision

A

5 V backplane load

25 mA

Isolated 24 V load

100 mA

Remote-node configuration marker

PNS version 1.00 for the base module class

03

Features

FUNCTIONAL DISTINCTIONS
01

Four current channels

Groups four process-current inputs in one rack module for controller acquisition.

02

Clear controller identity

The ALG IN 4 class helps the project distinguish this module from voltage and higher-density analog families.

03

Revision traceability

The A marking can be preserved with the rack slot and project record for controlled maintenance.

IndustryParts industrial parts support
INDUSTRIAL SPARE-PART SUPPORT

About IndustryParts

https://www.industryparts.com/

Controlled handling for IC694ALG221A

IndustryParts keeps the submitted IC694ALG221A identity, requested quantity and installed-system evidence together so a proposed supply can be checked before dispatch.

  • Complete submitted model retained
  • Installed-system evidence reviewed
  • Quotation record kept with the enquiry
04

Compatibility

SELECTION BOUNDARIES
A

Signal type

Confirm every connected transmitter and loop uses the current-input path expected by the project; voltage signals require the appropriate voltage module.

B

Rack and node

Verify the installed RX3i or Series 90-30 rack, remote-node support and configuration software before approving a spare.

C

Power budget

Include both the 5 V and isolated 24 V published loads in the rack calculation.

05

Replacement

SERVICE WORKFLOW
01

Capture

Record the A label, slot, channel ranges, conductor polarity and loop-power arrangement.

02

Exchange

Isolate affected loops and rack power, retain the approved terminal assembly and install the exact current-input module.

03

Test

Apply known current values to each used channel and verify engineering scaling, alarm response and diagnostics.

06

FAQ

CUSTOMER DECISION SUPPORT
Q01

Is IC694ALG221A a voltage-input module?

No. It is the four-point current-input execution; the similarly numbered IC694ALG220A is the voltage-input variant.

Q02

What power values matter for IC694ALG221A?

The manufacturer lists 25 mA from the 5 V backplane supply and 100 mA from isolated 24 V DC.

Q03

What should accompany a IC694ALG221A request?

Send the full A label, rack and slot, terminal style, loop ranges, polarity information and requested quantity.

Q04

Can IC694ALG221A be selected only by its four-channel count?

No. Signal type, rack support, project class and power budget must all match the installed record.

Q05

What commissioning evidence is suitable for IC694ALG221A?

Document known-current checks and the resulting engineering values, diagnostics and alarm behavior for every connected channel.