Home>PLC>Emerson IC694MDL742B PACSystems RX3i 16-Point 12/24 V DC Positive-Logic Output Module

Hot Categories

Emerson IC694MDL742B PACSystems RX3i 16-Point 12/24 V DC Positive-Logic Output Module

Emerson IC694MDL742B PACSystems RX3i 16-Point 12/24 V DC Positive-Logic Output Module

Item NO.: 3817006

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC694MDL742B PACSystems RX3i 16-Point 12/24 V DC Positive-Logic Output Module
  • Item NO.3817006
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandEmerson
  • Creation Time2026-11-02
SIXTEEN DC OUTPUTS · 12/24 V · 1 A · ESCP

Emerson IC694MDL742B PACSystems RX3i 16-Point 12/24 V DC Positive-Logic Output Module

A sixteen-point positive-logic DC output module with electronic short-circuit protection and the B revision retained.

Outputs16 points
Rating12/24 V DC, 1 A
ProtectionElectronic short-circuit protection
01
ASSET RECORD

Product Identification

IC694MDL742B is the B hardware revision of the Emerson PACSystems RX3i IC694MDL742 discrete output module. The base module provides sixteen 12/24 V DC positive-logic outputs rated at 1 A with electronic short-circuit protection.

The B revision, terminal assignment, group power and field-load schedule must remain together. Adjacent IC694MDL74x modules differ in polarity, output current and protective behavior, so selection by family number alone is insufficient.

The B revision preserves the installed hardware baseline for this protected sixteen-point positive-logic output module.
02
CONFIGURATION REGISTRY

Engineering Data

Product family
PACSystems RX3i I/O
Base catalog number
IC694MDL742
Exact revision
B
Output points
16
Output voltage
12/24 V DC
Output current rating
1 A
Logic
Positive
Protection
Electronic short-circuit protection (ESCP)
Installation
RX3i rack I/O position
Selection record
Terminal wiring, group supply and load schedule
03
OPERATING ROLE

Functions

01

Switch positive-logic field loads

Controls sixteen documented DC loads from the RX3i I/O system.

02

Protect output groups

Electronic short-circuit protection supports fault containment within the published design.

03

Report controller state

Provides point status and module diagnostics through the rack I/O architecture.

04
FIELD PLACEMENT

Applications

Solenoids and relays

Use where field voltage, steady current and inrush remain within the approved output design.

Panel discrete control

Maintain group supply, common and protective-device coordination in the cabinet record.

Revision-controlled maintenance

Match the B label and project hardware configuration before exchange.

05
MAINTENANCE CONTROL

Lifecycle

01

Record

Capture IC694MDL742B, rack slot, terminal map, group supplies and every connected load.

02

Review

Check inrush, suppression, duty cycle and protective-device coordination for all outputs.

03

Exchange

Isolate field energy and transfer conductors position-for-position under the approved procedure.

04

Prove

Command every used point and verify load response, fault indication and safe-state behavior.

IndustryParts industrial parts support
INDUSTRIAL SPARE-PART SUPPORT

About IndustryParts

https://www.industryparts.com/

Controlled handling for IC694MDL742B

IndustryParts keeps the submitted IC694MDL742B identity, requested quantity and installed-system evidence together so a proposed supply can be checked before dispatch.

  • Suffix and MOD identity kept visible
  • Mating hardware recorded before supply
  • Acceptance evidence linked to the order
07
PURCHASE AND SERVICE SUPPORT

FAQ

Q01

What distinguishes IC694MDL742B from IC694MDL741?

The MDL742 base is a 1 A positive-logic module with electronic short-circuit protection; nearby modules have different polarity or ratings.

Q02

What should accompany a IC694MDL742B enquiry?

Provide the B label, rack slot, terminal schedule, group supply and load current/inrush information.

Q03

Does ESCP eliminate the need for circuit review on IC694MDL742B?

No. Field protection, wiring capacity, suppression and load behavior still need engineering review.

Q04

Can the B revision be ignored when selecting a spare?

No. Retain it and verify the project and installed hardware baseline before substitution.

Q05

What proves IC694MDL742B is ready after replacement?

Document correct module recognition and successful operation and diagnostics for each active output.

You May Also Like