Home>PLC>Emerson IC694MDL754 32-Point 24 VDC High-Density Output Module

Hot Categories

Emerson IC694MDL754 32-Point 24 VDC High-Density Output Module

Emerson IC694MDL754 32-Point 24 VDC High-Density Output Module

Item NO.: 3331468

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC694MDL754 32-Point 24 VDC High-Density Output Module
  • Item NO.3331468
  • Weight0.2500 kg = 0.5512 lb = 8.8185 oz
  • CategoryPLC
  • BrandEmerson
  • Creation Time2025-08-28
RX3i OUTPUT · 32 POINTS · 24 VDC / 0.75 A

Emerson IC694MDL754 32-Point 24 VDC High-Density Output Module

A high-density RX3i discrete output module for thirty-two documented 24 VDC load circuits.

Outputs32
Voltage24 VDC
Published current0.75 A
01
PRODUCT DOSSIER

Product Overview

IC694MDL754 is the PACSystems RX3i 32-point high-density 24 VDC output module. Emerson identifies the article with a published 0.75 A current value; actual grouped loading and field protection remain part of the circuit design.

The large point count makes terminal and project discipline essential. Every output tag, connected load, safe state and suppression device should be retained before the module is removed.

Emerson release information requires 16 bits of module status to be configured for IC694MDL754; configuring zero status bits can create invalid ESCP status.

02
PUBLISHED CHARACTERISTICS

Performance

SIGNAL

High-density command output

Controls thirty-two discrete 24 VDC field points from one RX3i module position.

TRANSFER

Load-state transfer

Applies controller commands to documented field circuits under the approved grouping and protection scheme.

CONTROL

Module status reporting

Provides a status boundary that should be configured with the manufacturer-required 16 status bits.

EVIDENCE

Service localization

Allows channel and wiring evidence to be organized against one exact catalog identity.

03
ENGINEERING RECORD

Technical Details

Manufacturer
Emerson
Exact model
IC694MDL754
Product family
PACSystems RX3i
Module type
High-density DC voltage output
Output points
32
Nominal voltage
24 VDC
Published current value
0.75 A
Module status configuration
16 bits required
Known configuration risk
Zero status bits can produce invalid ESCP status
Selection record
Complete terminal and load schedule
DOCUMENTED INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

Exact-model handling for IC694MDL754

IndustryParts keeps the complete model label, requested quantity, application evidence and delivery requirements together so the proposed supply can be checked against the installed system before dispatch.

IndustryParts industrial automation supply support
04
SYSTEM PATH

System Integration

CAPTURE

Characterize all loads

Record voltage, steady current, inrush, suppression, safe state and terminal for each used output.

MATCH

Preserve status configuration

Confirm the hardware configuration allocates the required 16 bits of module status.

PROVE

Commission in controlled groups

Exercise outputs by machine function and prove de-energized states, interlocks and diagnostics.

05
FIELD CONTEXT

Applications

High-density actuator control

Switching documented 24 VDC solenoids, indicators and interface circuits.

RX3i cabinet consolidation

Providing thirty-two outputs from one engineered module position.

Controlled output replacement

Restoring the exact catalog while preserving load groups and module status behavior.

06
PROCUREMENT SUPPORT

FAQ

QUESTION 01

What should accompany an IC694MDL754 enquiry?

Send the complete label, rack and slot record, thirty-two-point output schedule, load currents, suppression details and hardware configuration.

QUESTION 02

Why must IC694MDL754 have 16 status bits configured?

Emerson release information warns that zero configured status bits can produce invalid ESCP status.

QUESTION 03

Does the 0.75 A value remove the need for a load calculation for IC694MDL754?

No. Grouped loading, inrush current, protection and cabinet temperature must still be checked for the actual installation.

QUESTION 04

How should unused points on IC694MDL754 be recorded?

Identify them as spare or reserved and keep their terminals protected so later work does not create an undocumented circuit.

QUESTION 05

What proves IC694MDL754 is ready after exchange?

Verify every commanded and safe state, status reporting, interlocks, fault response and stable operation under the approved load sequence.

You May Also Like