Home>DCS>Emerson IC695ACC400-AA RX3i Energy Pack

Hot Categories

Emerson IC695ACC400-AA RX3i Energy Pack

Emerson IC695ACC400-AA RX3i Energy Pack

Item NO.: 3786280

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC695ACC400-AA RX3i Energy Pack
  • Item NO.3786280
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-09
PACSYSTEMS RX3I | ENERGY PACK | AA REVISION

Emerson IC695ACC400-AA RX3i Energy Pack

An AA-marked IC695ACC400 energy pack for supported RX3i CPE controllers and controlled user-memory retention.

BrandEmerson / GE Intelligent Platforms
ModelIC695ACC400-AA
Product TypePACSystems RX3i CPU Energy Pack, Revision AA
01

Product Overview

IC695ACC400-AA is an AA-marked revision of the PACSystems RX3i CPU Energy Pack. Its function is to sustain a supported CPE controller long enough to copy user memory into non-volatile storage after loss of system power.

The complete AA suffix distinguishes the requested installed revision. It should be supplied with the compatible IC695CBL001 cable and verified against the exact CPE302, CPE305 or CPE310 controller platform.

02

Performance

  • Supplies the short-duration energy required by the controlled memory-save sequence.
  • Provides controller-visible charging, charged, low-capacitance and hardware-fault states.
  • Supports pack replacement without changing the separate real-time-clock battery function.
  • Mounts beside the rack module without consuming an RX3i backplane slot.
  • Operates over the documented 0 to 60 °C temperature range.
03

Technical Details

Manufacturer Emerson / GE Intelligent Platforms
Model IC695ACC400-AA
Base Catalog IC695ACC400
Revision Mark AA
Product Family PACSystems RX3i
Product Role CPU Energy Pack
Supported CPU Family Documented IC695CPE302, IC695CPE305 and IC695CPE310 platforms
Companion Cable IC695CBL001
Cable Length 0.91 m (3 ft)
Memory Function Powers the CPU long enough to save user memory to non-volatile storage
System Status %S0014 PLC_BAT indicates connected/healthy or missing/failed
Diagnostic States Charging, Charged, Low capacitance and Fault
Mounting Left side of an RX3i module, typically beside slot 0
Dimensions 25.4 mm W × 140 mm H × 124 mm D
Operating Temperature 0 to 60 °C
Enclosure Requirement At least NEMA/UL Type 1 or IP20, Pollution Degree 2
Time-of-Day Retention Separate RTC battery
User Service No internal user service
04

System Integration

  • Confirm the IC695ACC400-AA label, CPE catalog suffix and cable before ordering.
  • Create a verified controller backup and record all current energy-pack diagnostics.
  • Inspect the side-mount hardware, connector latch and cable routing before installation.
  • Wait for a fully charged indication and healthy %S0014 status.
  • Perform a controlled outage and verify memory restoration, controller mode and process restart behavior.
05

Applications

  • Revision-controlled RX3i CPE302/CPE305/CPE310 maintenance.
  • Battery-less preservation of controller user memory during system power loss.
  • Spare strategies that retain the exact AA product release and cable scope.
  • Preventive replacement after low-capacitance diagnostics.
06

FAQ

Can IC695ACC400-AA and IC695ACC400-CA be treated as the same stock item?

They share the IC695ACC400 base function, but the revision must remain visible and any substitution should follow the site qualification and label/approval review.

What is the main procurement risk with IC695ACC400-AA?

A pack can arrive without the IC695CBL001 cable or with an unverified suffix, so define revision, cable and mounting scope in the purchase order.

What should be done if IC695ACC400-AA reports low capacitance?

Schedule replacement under the controller procedure, preserve a current project backup and avoid relying on the pack for memory retention until health is restored.

How can IC695ACC400-AA be changed without losing user memory?

Keep the controller powered during the permitted replacement procedure, install the new pack, allow it to charge and then verify status before any power interruption.

Which test proves IC695ACC400-AA is ready for service?

A controlled power-loss and restart test with a verified backup confirms the energy pack, cable, memory-save process and intended controller recovery.

You May Also Like