Home>DCS>Emerson IC695CHS007 PACSystems RX3i 7-Slot Universal Backplane

Hot Categories

Emerson IC695CHS007 PACSystems RX3i 7-Slot Universal Backplane

Emerson IC695CHS007 PACSystems RX3i 7-Slot Universal Backplane

Item NO.: 3792240

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC695CHS007 PACSystems RX3i 7-Slot Universal Backplane
  • Item NO.3792240
  • Weight0.9200 kg = 2.0283 lb = 32.4520 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-13
Compact seven-slot RX3i system foundation

Emerson IC695CHS007 PACSystems RX3i 7-Slot Universal Backplane

A universal backplane for PACSystems RX3i power, CPU and I/O modules with revision-dependent controller compatibility.

ManufacturerEmerson
Exact modelIC695CHS007
Product typePACSystems RX3i 7-Slot Universal Backplane
01

Key Information

IC695CHS007 is the seven-slot universal backplane in the PACSystems RX3i family. It provides the mechanical and electrical base for a compact RX3i controller assembly.

Backplane revision is a compatibility item. Current CPE302, CPE305 and CPE310 guidance calls for IC695CHS007-AA or later, while -JC or later backplanes require controller firmware 10.85 or later.

02

Functions

01

Provides seven universal positions for supported RX3i power, controller, communication and I/O modules.

02

Distributes backplane power and the RX3i system buses across the installed module set.

03

Maintains module alignment, connector engagement and panel mounting for the controller assembly.

04

Supports compact PACSystems designs where a 12- or 16-slot backplane is not required.

03

Specifications

Manufacturer Emerson / legacy GE Intelligent Platforms
System family PACSystems RX3i
Backplane type Universal
Slot count 7
Supported module mix RX3i modules listed in the PACSystems RX3i system documentation
CPE302/CPE305/CPE310 minimum backplane revision IC695CHS007-AA or later
Later-revision firmware note IC695CHS007-JC or later requires controller firmware 10.85 or later
Series 90-30 CPU compatibility Series 90-30 CPUs do not operate in RX3i racks
Selection control Backplane suffix, CPU firmware and complete module list
04

Installation

  • Record every installed module, slot and backplane suffix before dismantling the rack.
  • Mount the backplane flat on a conductive panel and follow the RX3i spacing, grounding and cabinet-environment requirements.
  • Inspect all backplane connectors for damage or contamination before moving power supplies, CPU and I/O modules.
  • After rebuilding, verify CPU firmware against the backplane revision before downloading hardware configuration.
05

Lifecycle

  • Keep the backplane revision in the controller asset record because later hardware may change firmware requirements.
  • Photograph module order and keyed terminal assemblies before any rack replacement.
  • Use ESD controls and protect open backplane connectors while modules are removed.

About IndustryParts

https://www.industryparts.com/

Backplane revision is part of the controller design

IndustryParts treats IC695CHS007 as a system component and keeps the backplane suffix, CPU firmware and module map together.

  • Revision photographed
  • CPU firmware checked
  • Slot map retained
IndustryParts order verification support
07

FAQ

What information is needed to quote IC695CHS007 accurately?

Send the complete backplane label and suffix, CPU catalog number and firmware, power supply, and a slot-by-slot module list.

Can IC695CHS007 replace a Series 90-30 main rack?

No direct assumption should be made. Series 90-30 CPUs do not operate in RX3i racks, so controller and module compatibility must be redesigned or verified.

Why does the IC695CHS007 hardware suffix matter?

CPU support guidance changes by backplane revision; for example, -JC or later requires compatible controller firmware.

What should be checked on a used IC695CHS007 before installation?

Inspect every connector, mounting point, grounding surface and label, and reject evidence of arcing, corrosion, impact or board distortion.

How should an IC695CHS007 rack change be commissioned?

Confirm module order, power budget and CPU firmware, download the approved hardware configuration, then check diagnostics before enabling field outputs.

Enquiry Information

Send the complete IC695CHS007 label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807

You May Also Like