Emerson IC695CMM002-FK PACSystems RX3i Two-Port Serial Communications Module
A two-port RX3i serial communications module whose FK suffix must stay tied to the installed firmware and project record.
Technical Summary
PRODUCT CONTEXTIC695CMM002-FK is the FK hardware execution of the Emerson PACSystems RX3i IC695CMM002 two-port serial communications module. It adds serial device connectivity to the RX3i rack and is configured as a specialty module in the controller project.
Emerson publishes the base IC695CMM002 function as a two-port serial communications module. The FK suffix should be verified from the physical label and the installed project because firmware support and approved serial protocol settings are application dependent.
Specifications
CONTROLLED DATAPACSystems RX3i
IC695CMM002
Serial communications specialty module
2
FK
RX3i universal backplane
Hardware configuration retained in PAC Machine Edition
Complete label, firmware record and port configuration
Features
FUNCTIONAL DISTINCTIONSTwo independent serial paths
Provides two module-level serial connections for supported RX3i applications.
Rack-integrated configuration
The module identity and port setup are retained in the controller project.
Suffix-controlled spare
The FK execution stays visible so a base IC695CMM002 is not assumed to be identical.
Service evidence
Port wiring, protocol, baud rate and peer-device records support controlled replacement.
Compatibility
SELECTION BOUNDARIESController and project
Confirm the CPU firmware and PAC Machine Edition project support the installed CMM002 execution.
Serial settings
Match interface mode, protocol, baud rate, framing, station address and cable pinout per port.
Backplane position
Verify the RX3i rack slot and power budget before approving a spare.
Replacement
SERVICE WORKFLOWArchive
Save the project and record IC695CMM002-FK, firmware, rack slot and both port configurations.
Transfer
Isolate as required, move each labeled serial cable and preserve shielding and grounding.
Commission
Verify module recognition, port diagnostics and communication with every configured peer.
FAQ
CUSTOMER DECISION SUPPORTWhy is the FK suffix important on IC695CMM002-FK?
It identifies the installed hardware execution and should be matched against firmware, project and service records.
What port evidence should accompany a IC695CMM002-FK request?
Provide protocol, electrical interface, baud rate, framing, station address and cable identity for both ports.
Can a base IC695CMM002 be approved from the catalog number alone?
No. The FK label and installed software compatibility still need verification.
What should be backed up before removing IC695CMM002-FK?
Retain the complete PAC Machine Edition project plus any serial peer-device and cable documentation.
What closes a IC695CMM002-FK replacement record?
Confirm correct rack recognition, stable port diagnostics and successful data exchange with both configured serial networks.