Emerson IC695CPE305-AFBA PACSystems RX3i CPE305 Controller
A backplane-mounted RX3i controller with 6 MB user memory, integrated Gigabit Ethernet switching and an included energy pack.
Overview
Emerson IC695CPE305-AFBA is a pacsystems rx3i cpe305 controller identified by the complete submitted ordering string. Its suffixes and revision fields remain part of the supply identity.
Selection of IC695CPE305-AFBA should be based on the installed label, host-system record and the verified interface details below; neighboring family numbers are not treated as interchangeable.
Engineering Data
Functions
The 6 MB controller combines logic execution, data memory and multiple industrial communication services.
Two integrated two-port Ethernet switches provide flexible physical network connections.
The included energy pack supports controlled preservation of volatile operating data.
PROFINET remote I/O can be integrated through the documented PNC architecture.
Applications
- RX3i machine and process-control applications requiring integrated Ethernet communications.
- Controller replacement where the AFBA release, energy pack and engineering-software record are preserved.
- PROFINET systems using compatible PNC modules and approved network design.
Lifecycle & Service
- Export the complete PAC Machine Edition project and record firmware, AFBA label and energy-pack status.
- Document every Ethernet port, IP address, protocol service and PROFINET device before shutdown.
- Confirm project and firmware compatibility before download; do not use another CPE305 suffix as proof.
- Test logic, time synchronization, communications, remote I/O and controlled shutdown behavior.
FAQ
What should accompany an IC695CPE305-AFBA replacement request?
Provide the complete controller label, firmware, PAC Machine Edition project version, energy-pack status, network configuration and installed option-module list.
How does the energy pack affect IC695CPE305-AFBA maintenance?
Its condition and connection must be included in the replacement plan because the controller uses it for controlled preservation of operating data.
Can IC695CPE305-AFBA be exchanged solely from the base CPE305 number?
No. Retain the AFBA release identity and compare firmware, project compatibility, approvals and hardware records before exchange.
When is MRP relevant to IC695CPE305-AFBA?
MRP is relevant when the controller is engineered with compatible PNC-based PROFINET redundancy; the installed network roles and recovery design must be preserved.
What acceptance tests should follow IC695CPE305-AFBA installation?
Verify the project checksum, energy-pack status, every Ethernet service, serial communications, local and remote I/O, alarms and machine interlocks.

