Runs RX3i control applications with one control engine and the PACSystems engineering environment.
Technical Summary
IC695CPE330-ABAF is a release-specific execution of the PACSystems RX3i CPE330 controller. The CPE330 provides a dual-core 1 GHz control platform, 64 MB of user memory and embedded Ethernet connectivity.
The controller supports high-availability network designs through Media Redundancy Protocol and PROFINET System Redundancy. The full ABAF suffix must remain visible because hardware and firmware release identity can affect a replacement decision.
Project backup, firmware record, rack configuration, network names and the installed CFast record should be captured before exchange.
Specifications
| Manufacturer | Emerson |
|---|---|
| Exact model | IC695CPE330-ABAF |
| Controller family | PACSystems RX3i CPE330 |
| Form factor | Backplane, two-slot controller |
| Processor | Dual core, 1 GHz |
| User memory | 64 MB |
| Discrete I/O capacity | 32K bits |
| Analog I/O capacity | 32K words |
| Ethernet interfaces | Three 10/100/1000 ports; two are switched |
| Redundancy support | MRP and PROFINET System Redundancy |
| USB interface | One USB-A 2.0 |
| Memory card | One CFast interface |
| Operating temperature | 0 to 60 °C |
| Release identity | ABAF suffix retained from the submitted label |
Features
Provides embedded Gigabit Ethernet connectivity for controller and industrial-network communications.
Supports controller-side redundancy and remote-I/O architectures when the required companion hardware is present.
Uses the complete catalog and release code to separate this unit from other CPE330 revisions.
Compatibility
- Confirm PAC Machine Edition version, CPU firmware and project target before loading the application.
- Verify the RX3i backplane, power supply, energy-pack arrangement and occupied two-slot position.
- Record every Ethernet address, PROFINET device name, redundancy role and switch connection.
- Do not treat another IC695CPE330 suffix as automatically interchangeable with IC695CPE330-ABAF.
Replacement
- Export the controller project and collect configuration, firmware, network and fault records before shutdown.
- Follow the approved controller power-down and process-state procedure before removing the CPU.
- Install the verified release, restore the validated project and re-establish all network identities.
- Prove I/O exchange, communications, redundancy transitions, retained data and affected safety interlocks.
FAQ
Q01
What release evidence should accompany an IC695CPE330-ABAF enquiry?
Provide clear front and side labels, firmware revision, PAC Machine Edition project target, backplane position and a photograph of the connected ports.
Q02
Can a base IC695CPE330 be quoted without preserving the ABAF suffix?
The family identity alone is insufficient for a controlled spare. The quoted unit should be checked against the installed ABAF release and approved firmware baseline.
Q03
Which configuration records reduce commissioning risk for IC695CPE330-ABAF?
Retain the project archive, Ethernet addressing, PROFINET names, redundancy settings, CFast contents and any licenses tied to the controller.
Q04
What companion hardware should be checked before replacing IC695CPE330-ABAF?
Verify the RX3i backplane and power supply, energy-pack arrangement, remote-I/O controllers, network topology and any redundancy partner.
Q05
What proves IC695CPE330-ABAF is ready to return to service?
A controlled test should show correct project checksum, healthy I/O, stable communications, expected redundancy behavior and successful process-permissive checks.
About IndustryParts
https://www.industryparts.com/Controller enquiries preserve the full release and project baseline
IndustryParts records IC695CPE330-ABAF together with its controller release, firmware, project and installed network evidence.
- ABAF release retained
- Project and firmware records requested
- Network and redundancy roles cross-checked