Exchanges periodic controller data with Ethernet Global Data and supports EGD command access.
Key Information
IC695ETM001-LBAA connects a PACSystems RX3i controller to Ethernet networks used by other PACSystems, Series 90 and VersaMax controllers, programming stations and host systems.
The LBAA entry is a documented October 2021 release with Ethernet firmware 7.06 (EG67). Its label update is part of the exact revision identity, so IC695ETM001-LBAA should not be shortened to the base catalog number in procurement records.
Functions
Provides SRTP programming, configuration, monitoring and TCP/IP communications.
Supports Modbus TCP server and client channels for documented controller integrations.
Uses an internal switch with auto-negotiation, speed sensing and crossover detection.
Specifications
| Manufacturer | Emerson PACSystems |
|---|---|
| Exact Model | IC695ETM001-LBAA |
| Platform | PACSystems RX3i |
| Product Type | Ethernet interface module |
| Release | October 2021 |
| Ethernet Firmware | Version 7.06 (EG67) |
| Network Ports | Three shielded RJ45 ports |
| Port Speeds | 10Base-T, 100Base-TX and 1000Base-T |
| Network Interfaces | One LAN interface across two switched ports plus a separate front-panel Station Manager interface |
| IP Addresses | Two: one for the switched LAN ports and one for the front-panel interface |
| Protocols | SRTP, Modbus TCP and Ethernet Global Data |
| SRTP Capacity | 32 SRTP channels; up to 48 simultaneous SRTP server connections |
| Network Services | Programming, configuration, online monitoring and SNTP time synchronization |
| Redundancy Feature | Configurable stand-alone redundant IP address |
| Hardware Class | Kxxx-or-later Ethernet platform |
| CPU Firmware for Full Feature Support | CPE330/CPE302/CPE305/CPE310 9.90; CPU315/CPU320/CRU320 8.95 |
| Topology Caution | Use a tree through the switched ports; do not create an unmanaged ring |
Installation
- Record both configured IP addresses, subnet, gateway, redundant IP, EGD exchanges and channel definitions before removal.
- Confirm the target RX3i backplane revision and CPU firmware meet the LBAA feature requirements.
- Reconnect the two switched LAN ports and the Station Manager port by function, not merely by physical position.
- Keep the physical network in a tree unless an engineered ring technology is provided elsewhere; the built-in switch alone must not close a loop.
- After installation, verify link speed, Station Manager access, programmer connection, SRTP/Modbus channels, EGD production and time synchronization.
Lifecycle
- Retain the IC695ETM001-LBAA label and firmware build in the asset record.
- Back up PAC Machine Edition hardware configuration and any Advanced User Parameter file.
- Review cybersecurity, switch configuration and IP-address ownership before cutover.
- Trend CRC, collision, late-collision and duplicate-address symptoms during the acceptance window.
About IndustryParts
https://www.industryparts.com/Ethernet identity and firmware stay traceable
IndustryParts keeps IC695ETM001-LBAA tied to its LBAA hardware label, 7.06 firmware baseline and the installed PACSystems network record.
- Exact LBAA label retained
- IP plan recorded
- CPU compatibility reviewed
FAQ
Why can IC695ETM001-LBAA link LEDs be on while controller traffic is unreliable?
Duplex mismatch, duplicated addressing, a closed network loop or mismatched EGD and channel definitions can preserve link while disrupting application traffic.
What evidence is needed before quoting IC695ETM001-LBAA?
Provide the complete label, current firmware, CPU and backplane revisions, port use, IP plan and exported PAC Machine Edition configuration.
Can an earlier IC695ETM001 revision replace IC695ETM001-LBAA without review?
No. The LBAA hardware is on the Kxxx-or-later platform and adds port, speed, Station Manager and software-compatibility boundaries that must be checked.
How should IC695ETM001-LBAA redundant IP operation be accepted?
Test ownership by the active controller, switchover, EGD production source, client reconnection and recovery without creating simultaneous address use.
What should be checked if IC695ETM001-LBAA negotiates the wrong speed?
Inspect cable category, shielding, switch configuration and auto-negotiation at both ends; manual speed or duplex settings must agree on both link partners.