Emerson IC695HSC304-FA PACSystems RX3i High-Speed Counter Module
An FA hardware execution of the RX3i 1.5 MHz high-speed counter module with eight inputs and seven outputs.
Product Overview
IC695HSC304-FA is the FA execution of the PACSystems RX3i high-speed counter module. Emerson identifies the base IC695HSC304 as a 1.5 MHz module with eight inputs and seven outputs.
The FA suffix is retained as a hardware identity. Counter mode, input wiring, output assignments and project configuration must come from the installed application rather than from the suffix alone.
Performance
Capture high-speed events
Processes the configured counting or position signals within the published module speed class.
Coordinate dedicated outputs
Uses the seven outputs according to the approved counter application and controller logic.
Expose module diagnostics
Provides status needed for setup, troubleshooting and acceptance.
Technical Details
| Manufacturer | Emerson / GE Fanuc | Exact model | IC695HSC304-FA |
|---|---|---|---|
| Base catalog | IC695HSC304 | Product family | PACSystems RX3i |
| Product type | High-Speed Counter Module | Maximum counter class | 1.5 MHz |
| Inputs | 8 | Outputs | 7 |
| Hardware identity | FA suffix retained | ||
System Integration
Archive configuration
Export counter modes, presets, filter values, input assignments and output logic.
Capture wiring
Photograph every high-speed signal, shield and terminal position.
Install by revision
Confirm the FA label and supported RX3i project before exchange.
Prove motion signals
Test reference, count direction, limits and configured outputs at controlled speed.
Applications
High-speed counting
Acquiring documented pulse trains within the approved RX3i counter application.
Position-related logic
Coordinating counter state with configured controller outputs and machine interlocks.
Revision-controlled service
Replacing the exact FA execution while retaining application parameters.
FAQ
Q01What project data should accompany a IC695HSC304-FA enquiry?+
Provide the FA label, rack and slot, firmware, counter modes, filter settings, presets, I/O map and project backup.
Q02Can IC695HSC308 replace IC695HSC304-FA?+
Not directly. The HSC308 has a different I/O architecture, so hardware, wiring and project compatibility require engineering review.
Q03What wiring evidence matters most for IC695HSC304-FA?+
Record signal source, voltage class, shield termination, common reference and every input/output terminal.
Q04Why should the FA suffix be retained for IC695HSC304-FA?+
It keeps the exact installed hardware release attached to the project and spare record without assuming unsupported revision details.
Q05What proves IC695HSC304-FA is commissioned correctly?+
Controlled pulse tests, correct direction and preset behavior, verified outputs and clean RX3i diagnostics provide acceptance evidence.
About IndustryParts
https://www.industryparts.com/High-speed modules are checked against both wiring and project data
IndustryParts records the FA hardware identity, counter configuration, signal map and requested quantity before supply review.
- •Exact submitted model retained
- •Installed-system evidence reviewed
- •Requested quantity linked to the enquiry
Request a model-specific quotation
Send the complete IC695HSC304-FA label, requested quantity, delivery destination and installed-system context.